30
ENGLISH
1 – Description of Cabinet
The refrigerated cabinets in the SIRIUS-ORIONE line are multiplexable units with a usable internal length of 937 mm
(MODEL 100), 1250 mm (MODEL 135), 1875 mm (MODEL 200), 2500 mm (MODEL 260) and 3750 mm (MODEL 385).
All models use a system of forced air ventilated refrigeration, with remote unit. The general aesthetic characteristics and
overall dimensions are clearly illustrated in FIG. 1 on page 1 and the main information and characteristics in TAB. 1 on
page 3.
2 - Handling the unit
The unit comes on wooden runners (wooden crating available on request) to facilitate handling by forklift. Only authorised
expert personnel should handle the unit. TAB. 1 on page 3 shows the weight of the units and FIG. 2 on page 2 shows fork
lengths of the relative lifting points.
3 - Receipt and storage
On delivery, make sure the unit has not been damaged during transport. Check the condition of the packaging: if the
packaging is damaged, check the contents in the presence of the carrier. For storage, make sure that the unit is protected
against the weather and stored at a temperature between -25°C and +55°C; 30-95% relative humidity. Take special care
when unpacking the unit, as the packaging contains various parts and/or accessories needed to complete the display unit
(spacers, raised edges, etc). Place the display unit exactly where you plan to install it. Move the unit properly:
never drag
by its sides!
Warning:
Inform the Manufacturer immediately if the unit arrives damaged. Any delay in doing so relieves the
Manufacturer of all liability. The Manufacturer is not liable for any damage to the unit during handling and storage.
4 - Installation and environmental conditions
The unit should be placed on a perfectly flat floor (please refer to FIG. 6 page 2). When fully loaded, the display cabinet
should not vibrate. The efficiency of the unit may be endangered if it is not perfectly levelled! First of all raise the
multideck, then unscrew the feet (FIG. 3 at page 2), remove the wooden runner (FIG. 4 at page 2), set the siphons (FIG.
5 at page 2), level the cabinet (FIG. 6 at page 2), assemble the bottom trim and its kickplate (FIG. 7 at page 3). The
display cabinet should never be placed in areas where explosive gas substances are used. The unit should not be left
outdoors or exposed to the rain (see FIG. 12 on page 4).
The performance of the cabinet refers (according to the international standard
EN ISO 23953-1/2
) to environmental
climatic class 3 which consists of a room temperature of 25°C with relative humidity of 60%.
Performance may suffer if the environmental conditions differ from those foreseen, or the cabinets are exposed to air
flows of more than 0.2m/sec or sources of heat. To avoid this problem, the User should send the Manufacturer details of
the environmental conditions before finalising the design of the units, so that the technical parameters and material
options can be modified and the installer informed of the refrigerating power actually required
.
5 - Electrical connections
Electrical connections must be handled by qualified personnel only, according to current laws. For the connections please
refer to electrical diagrams from page 11 to page 22.
Warning:
Before connecting the unit to the mains, make sure that the mains voltage corresponds to that indicated on the
serial plate (bearing in mind that the max acceptable variations in voltage are +/-10%). Check that the cables used has
the proper cross-section and length to withstand the current and the power absorbed by the combination, as indicated in
TAB. 1 on page 3.
Warning:
Follow the Manufacturer's instructions to install the unit, using qualified personnel and
complying with the electrical regulations for the specific country (electrical safety standards and laws, accident and fire
prevention laws, EC directives). Incorrect installation may cause injury and damage; the Manufacturer is not liable for this.
The unit must be earthed. The Manufacturer is not liable for any damage or injury should this safety regulation be
ignored. If the unit is to be installed far from the electrical sockets, suitable electrical connections are needed and these
must comply with the prevailing standards. The use of adapter plugs is strictly prohibited.
The Manufacturer is not liable
for any damage or injury arising from incorrect installation.
6 - Technical details
The display unit is delivered with a plastic envelope containing this instruction manual. This manual must be kept with the
machine. It contains all the technical data, wiring diagrams and tables needed for the unit.
The following technical data are also shown on the serial plate (FIG. 9 on page 3):
1. Commercial name of the refrigerating display unit
2. Refrigerating display unit code
3. Refrigerating display unit serial number
4. Rating
5. Frequency
6. Max absorbed current
7. Max absorbed power
8. Max absorbed power during defrosting