UNIT CONTROLS 

 

 

The blowers and automatic fuel supply are controlled from the panel on the HYBRID-35. The control panel functions are as follows: 
 
Note:  

1- 

To display the available functions, just touch the control board at any place 

2- 

Select the desired function 

*The display will turn itself off after 2 minutes.

 

 
 

MODE BUTTON 

   

 

 

 

When the on-off button is pressed,  the stove will automatically ignite.  The heat level must be selected manually to adjust the stove’s heat output to 
the desired level.  If the thermostat mode is selected, the stove will automatically modulate between the lowest heat level and the heat level 
selected to keep the room temperature at the thermostat’s setting. If the set room temperature is achieved  while the stove has been running at the 
lowest heat level for more than 45 minutes, the unit will automatically shut off and will start another ignition cycle only when the thermostat calls for 
heat again(stove has to cool down completely before igniting again).  No  fire starter is necessary to ignite the unit. The auger will feed fuel for 4 
minutes and the electronic igniter will stay on for 10 minutes.  If  the unit doesn’t ignite within 15 minutes, the stove will wait for 5 minutes and will 

start a second ignition cycle. If  ignition fails a second time, a warning message 

 

will appear on control panel. 

 

 

The Heat Level may be selected during the ignition cycle and can be modified in heating mode. However, the unit will only feed fuel at the desired 
heat level setting when the heat sensor located into the stove receives a signal indicating that the unit has ignited.  This may  take anywhere 
between 10 and 15 minutes. 

 

FUEL FEED SWITCH 

 

 

 

By activating this function, the stove will feed for 1 minute and the display will blink.  You can stop the distribution by touching the sign a second 
time or by starting the stove. 

 

CAUTION:

 THIS FUNCTION CAN ONLY BE OPERATED WHEN THE STOVE IS IN “OFF” POSITION.  THE FUEL FEED SWITCH IS USED TO 

PRIME THE AUGER WHEN THE AUGER IS EMPTY. 

 

NOISE REDUCER

 

 

 

 

The convection blowers speed varies according to the fuel feed rate.  A dimmed display indicates that the blowers is in low noise mode. 

 

When the “NOISE REDUCER” button is pushed, the convection blowers will switch to their lowest speed. The convection blowers will remain at 
their lowest speed unless the stove reaches a certain temperature.  If this occurs,  the convection blowers will go back to its highest setting to cool 
down the stove.  The low noise button will have to be pressed again for the convection blowers to go back to their lowest speed. 

 

HEAT LEVEL 

 

 

 

By pressing the gradient, you can set the pellet feed rate and hence the heat output of your stove. The levels of heat output will change and each 
gradient will indicate the level from 1 to 6. 

 

RESET 

 

 

The reset icon is used to clear any warning on the control before restarting your stove.  This icon is only visible when you have a warning code on 
the display. 

OPENING DOOR 

 
The door should be opened only for maintenance purposes. 
 

CONVECTION BLOWERS (ROOM AIR FANS) 

 
Upon starting your stove, the convection blowers will not come on until the stove’s heat exchanger has warmed up. This usually takes about 10 to 15  
minutes from start-up.  Speed will vary with the selected feed rate, except if the noise reducer mode has been activated. 

Содержание HYBRID-35

Страница 1: ...y damage bodily injury or even death Save these instructions Some surfaces become hot at higher feeding rates To prevent potential burns avoid contact with those areas This heating unit must serve as...

Страница 2: ...wood only Do not burn coal of any type in this appliance It is designed for residential installation according to current national and local building codes as a freestanding or insert room heater It i...

Страница 3: ...in summer time may cause the heat sensors on the stove to activate the blowers disconnect the stove when not used for extended periods Contact your local building officials to obtain a permit and info...

Страница 4: ...2 INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY 12 INSERT INSTALLATION 13 INSERT INTO EXISTING MASONRY FIREPLACE 13 CLEARANCES 14 DOOR OVERLAY INSTALLATION 14 OPERATION 15 PROPER FUEL 15 PRE START UP C...

Страница 5: ...G CODE I 28 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE O 28 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE H 29 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE d 29 SMOKE SMELL COMING B...

Страница 6: ...e installed in front of the heat exchanger The black knob must be attached to the heat exchanger rod The pedestal kits must be assembled to the body freestanding version The faceplate kit must be asse...

Страница 7: ...ceramic tile or any tile must be laid on a continuous non combustible sheet to prevent the possibility of embers falling through to the combustible floor if cracks or separation should occur in the fi...

Страница 8: ...use a listed pellet vent that meets the ULC S 609 M89 and ULC ORD C441 M90 Standards For the United States we recommend that you use a listed pellet vent that meets the UL 641 7 th edition Standard Th...

Страница 9: ...sure that they are cleaned on a regular basis as per our recommended maintenance schedule This is particularly critical if you have animals in your house such as a dog or a cat Filters that are not c...

Страница 10: ...ot of horizontal run see Appendix A At least 3 feet of vertical rise are needed in all cases A longer vertical rise will favour a better exhaust 6 To reduce the risk of smoke spillage never terminate...

Страница 11: ...r square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof along upper edge Do not nail lower edge Seal nail heads...

Страница 12: ...ter of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to cut out the masonry around the location of the pipe center mark Cut a 4 inch diameter hole for 3 inch pipe and...

Страница 13: ...A through the floor Option B through the back wall Option C through chimney top 5 Attach the DuraVent adapter a section of pipe and clean out tee making sure the clean out tee is centered in the chim...

Страница 14: ...LLATION In order to complete the assembly of your OSBURN HYBRID 35 you need to install the door overlay Figure 37 Door overlay installation 1 Position the overlay on the door frame and fix it in place...

Страница 15: ...CK Remove burn pot making sure it is clean and none of the air holes are plugged Clean the firebox and then reinstall burn pot Clean door glass if necessary a dry cloth or paper towel is usually suffi...

Страница 16: ...s a signal indicating that the unit has ignited This may take anywhere between 10 and 15 minutes FUEL FEED SWITCH By activating this function the stove will feed for 1 minute and the display will blin...

Страница 17: ...corative panel for the insert This control is used to adjust the air intake manually depending on the type of installation and different brands of pellets used It allows you to improve the efficiency...

Страница 18: ...OTE If an overheating situation occurs the high temperature switch called the L 250 manual reset will automatically shut down the auger motor fuel feed system and a warning code will appear b If the c...

Страница 19: ...wall thermostat or a hand held thermostatic remote control you can locate the receiver behind the stove s back panel on the right side just below the terminal block Most receivers are already equippe...

Страница 20: ...mostat does not call for heat after 45 minutes the unit will remain at the lowest heat setting 1 but will not shut down this is the PILOT ON mode The stove will remain at the lowest heat level until t...

Страница 21: ...your stove is not connected to a thermostat or a fresh air supply do not leave it at the maximum setting If the ambient air becomes to hot the stove may overheat and the thermal protection on the com...

Страница 22: ...e firebox into the ash drawer through the opening at the bottom of the firebox or vacuum to remove ashes WARNING Make sure ashes are cool to the touch before using a vacuum See VACUUM USE f Periodical...

Страница 23: ...ure that the open side of the baffle is located on the left c Chamber walls Periodically you must vacuum the ashes that may have accumulated on the main walls of the combustion chamber START BY REMOVI...

Страница 24: ...CONNECTOR Figure 50 Exhaust blower cleaning CHIMNEY CLEANING a Creosote Formation When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creo...

Страница 25: ...t Blower Vacuum Pressure Switch Tap Brush Venting System Inspect Sweep Gaskets Inspect Hopper Empty Vacuum Gasket around door and door glass should be inspected and repaired or replaced when necessary...

Страница 26: ...xhaust pipe are blocked with ash or foreign material Follow all cleaning procedures in the maintenance section of the owner s manual 3 Vent pipe is incorrectly installed Check to make sure vent pipe i...

Страница 27: ...shaft from the auger housing Start by emptying the hopper Take off the rear panel of the stove s body Then remove the auger motor by removing the screws holding the motor to the auger shaft Once the m...

Страница 28: ...n occurs call your dealer or technician 5 The control board is not sending power to the igniter Check the voltage going to the igniter during ignition It should be a full current If the voltage is low...

Страница 29: ...aintenance procedures Press simultaneously for 2 seconds and icons After 3 attempts reset is no longer possible Call SBI technical support STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE d Possible...

Страница 30: ...the vent pipe has been installed according to the instructions in the owner s manual 3 The air damper is too far closed for a higher setting Slide the air supply to a higher setting and try to burn th...

Страница 31: ...erted polarity in power outlet Will not keep the stove from operating Power outage Igniter fuse blew up SMOKE SMELL OR SOOT BUILD UP Because it is a wood burning device your HYBRID 35 may emit a faint...

Страница 32: ...BLOWER CONVECTION BLOWER EXHAUST AUGER MOTOR Figure 53 Components rear GH TEMPERATURE WITCH L 250 ANUAL RESET HIGH TEMPERATURE SWITCH L 250 AUTOMATIC HIGH TEMPERATURE SWITCH F 160 AIR SUPPLY CONTROL I...

Страница 33: ...urn pot gasket 2 requires 21045 Control Board Touch screen 44022 PC Board 44102 Combustion Exhaust Blower Assembly SE44101 Convection Blower 44100 Door Gasket AC06100 Hot Rod Igniter 44030 Thermistor...

Страница 34: ...tal vent coming out at the back of the stove on a total distance of 4 feet followed by a Tee and a 6 foot vertical rise it would be acceptable The installation would end be within the allowable config...

Страница 35: ...uivalent vent lenght calculation table DRAW YOUR INSTALLATION 1 SQUARE 1 F00T PART DAILY 10 bags 25 bags E xchanger Baffle Left interior channel Hopper Evacuation blower Blower blades Pressure system...

Страница 36: ...ased on predetermined rate schedule and must not exceed the wholesale price of the replacement part All labour and freight costs covered by this warranty are limited according to the table below The m...

Отзывы: