5
6. OPENING SIZE: Refer to “Suitable Fireplace Dimensions” (Sec. 2.2) for suitable size
fireplace
openings.
NOTE:
A METAL TAG IS PROVIDED AND IS TO BE FASTENED TO THE BACK
WALL OF THE FIREPLACE IF THE FIREPLACE HAS BEEN MODIFIED TO
ACCOMMODATE THE INSERT.
2.2. VENTING REQUIREMENTS
The flue is a critical component to a satisfactory installation. Your insert will attain its best
performance if installed with a flue that generates its own draft. The minimum venting requirement
will be the installation of a flue connector from the insert into the first tile of the chimney (see
Figure 3.3). If you are using a masonry chimney, it is important that it be built in compliance with
the specifications of the National Building Code or other applicable standard having jurisdiction. It
must be lined with fire clay bricks, metal or clay tiles sealed together with fire cement (round flues
are the most efficient). Ideally, the interior diameter of the masonry chimney should be identical to
the insert smoke exhaust. You may also run a stainless steel liner inside the masonry chimney. A
continuous 6" (152mm) stainless steel liner from the top of the chimney to the insert’s smoke
exhaust (see Figure 3.2) is the optimum system and will provide the best performance, as well as
compensate for poor draft situations caused by large cross-sectional chimneys. The insert will not
work without a positive seal in the chimney.
Chimneys constructed outside of the home, on an exterior wall, should be avoided if possible,
especially in colder climates. Outside chimneys may not draw as well and may downdraft due to
the difficulty in heating them up to operating temperature. Cooler chimneys will result in increased
creosoting, less draft, and poorer performance. Draft is proportional to overall chimney height as
well as to stack temperature. Draft can be increased by increasing chimney height, and by
reducing heat loss from the chimney through an insulated liner.
Ensure that all joints in the flue systems are tightly sealed, since any leaks will result in reduced
performance as well as a possible safety hazard. Using a fire screen at the extremity of the
chimney requires regular inspection in order to insure that it is not obstructed thus blocking the
draught, and it should be cleaned when necessary.
Do not connect this unit to a chimney flue serving another appliance.
This heating unit must serve as a supplementary heat source. An alternate heat source should be
available in the home if needed. The manufacturer cannot be responsible for additional heating
costs associated with the use of an alternative heat source.
It is recommended that the user buys this product from a retailer who can provide installation and
maintenance advices.
Содержание 2000-I E.P.A.
Страница 32: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...
Страница 60: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...
Страница 88: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...
Страница 116: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...