20
6.
Ideally the large kindling should be burned until a thick bed of red embers is obtained. At
that point, add cordwood fuel and continue to operate the draft control wide open until the
fire is well established. Once the firebox is hot, the draft control can be partially closed by
pushing the knob to adjust the intensity of the fire.
Use Table 4.2 to adjust the draft control to the desired burn rate:
Draft Settings
Burn Rate
Draft Setting
Low
Push Control to end of travel.
Medium Low
Pull Control by 3/8” from closed position.
Medium High
Pull Control by 3/4” from closed position
High
Pull Control to end of travel.
Table 4.2
Closing the draft control down too soon will lower combustion efficiency, and may result in
creosote build-up in the chimney (which could lead to a chimney fire).