4.5.  MAINTAINING THE FIRE 

 

Your Osburn insert will work best if a thick bed of hot embers is maintained in the bottom of 
the firebox, and a minimum of two large pieces of seasoned fuel are added.  Combustion 
efficiency is largely related to establishing a hot ember bed, and hot firebox temperatures.  
The quicker the insert and fuel get up to operating temperature, the better.  A small intense 
fire is preferred to a large smouldering fire, both to improve combustion efficiency and to 
reduce the amount of creosote emitted. The best performance will be achieved by adding 
relatively small amounts of fuel to a well established ember bed, and then operating with the 
air inlet control open long enough to achieve a hot fire.  Cordwood should be placed with air 
in between individual pieces. Use a poker to make an air channel in the embers below the 
wood, this will allow air to flow under the wood for a more efficient burn. 
Extended burn times can be accomplished by first operating the insert on a full load with the 
air inlet controls wide open. Once the fire is well established, and the moisture has been 
driven out of the wood, reduce the air control to a lower setting.  The unit should then burn 
cleanly without smouldering.  If the fire smoulders without flame, re-establish a hotter fire 
before moving the air control to the lower setting. A yellow flame burning in the top of the 
firebox is a good indication of a clean efficiently burning fire. 
 
Refuelling technique is important for good performance.  The best efficiency and performance 
from your insert can be achieved by adding partial loads of fuel and allowing them to get up to 
operating temperature before adding additional fuel.  Adding a large amount of fuel at one 
time  will  increase  the  time  required  to  get  the  fuel  up  to  its  ignition  temperature, and an 
extended time to reach optimal performance.  When refuelling, open the air control or hold 
the door partially open 1” (25 mm) or less, long enough (less than 5 minutes) so that the fire 
has well established flames.  When refuelling, care is required to ensure that fuel or embers 
do not fall out of the door opening.   
 
In order to achieve an optimum efficiency from your unit, we suggest that you operate it with 
the air control slightly open (approximately 10%).  Make sure that you have a good fire going 
and an adequate ember bed before you completely close the air control.  Closing the air 
control  too  soon  will  lower combustion  efficiency  and  may  cause  the  fire  to  die  out.  The 
addition of a blower (if not already included)  is highly recommended to maximize your unit’s 
efficiency. 

Содержание 2000-I E.P.A.

Страница 1: ...NUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD INSERT Verified and tested following ULC S628 and UL 1482 Standards by Stove Builder International Inc 250 rue de Copenhague St Augustin...

Страница 2: ...mage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Keep and sa...

Страница 3: ...INSTALLATION INSTRUCTIONS OPTIONAL 12 3 8 BAFFLE INSTALLATION 13 3 9 SECONDARY AIR TUBE REPLACEMENT 14 3 10 REMOVAL INSTRUCTIONS 15 Section 4 0 OPERATION 16 4 1 SAFETY INFORMATION 16 4 2 CORDWOOD FUEL...

Страница 4: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 5: ...manufacturer s specs and code conformity The chimney must be of at least 1 25 mm larger in diameter to accommodate a required continuous stainless steel liner running from the flue collar to the top o...

Страница 6: ...mpensate for poor draft situations caused by large cross sectional chimneys The insert will not work without a positive seal in the chimney Chimneys constructed outside of the home on an exterior wall...

Страница 7: ...to any combustibles as mentioned on your insert certification label See figure 3 1 and table 3 1 Figure 3 1 CLEARANCES MINIMUM MASONRY OPENING A 13 330 mm F 24 610 mm B 22 559 mm G 29 737 mm C 10 254...

Страница 8: ...front of the insert is included in the calculation of the floor protector s dimensions Convert specification to R value k factor is given with a required thickness T in inches R 1 k x T C factor is g...

Страница 9: ...um floor protection for combustible floor materials as specified in this manual Floor protection to the front is to be measured from the fuel loading door opening 5 Osburn recommends that you install...

Страница 10: ...he room This creates a potential health hazard 3 CONNECTOR INSTALLATION A flue connector may provide acceptable performance however we recommend the use of a chimney liner to ensure satisfactory perfo...

Страница 11: ...inished side down on a flat soft non abrasive surface 2 Assemble the faceplate trim attaching the mitered corners with the corner brackets see Figure 3 5 3 Line up the holes of the side and top panels...

Страница 12: ...lay see Figure 3 7 Figure 3 7 2 Flip over both parts with the finished side on a plane and smooth surface free from dirt to avoid any scratches Align the holes of the door to those of the overlay Fix...

Страница 13: ...Open the rectangular outlet on the side of the unit by gently removing the material held in place by micro joints Use pliers Note The fresh air intake may be installed on the right or left end side o...

Страница 14: ...any damaged firebricks replaced Check the firebricks annually for damage and replace if they are broken or damaged See Figure 3 8 and 3 9 for the firebrick layout Install the side back firebricks firs...

Страница 15: ...r using a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baffle Importan...

Страница 16: ...ur insert Unscrew the faceplate fastener holding the faceplate to the faceplate extension Remove faceplate by pulling on it Remove faceplate extension Unclip the blower assembly Remove the three screw...

Страница 17: ...spillage or a back draft causing flame or smoke to spill into the room 5 Never use gasoline type lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or freshen a fire...

Страница 18: ...this is not done it could cause poor air quality in the home poor and incomplete combustion and poor efficiency in the insert Adequate ventilation is required to reduce effects from room air starvatio...

Страница 19: ...moisture content of 20 or less are ideal Dry seasoned wood can be distinguished from green wood by the checks or cracks in the ends 4 Wet or green wood will tend to cause the fire to smoulder produci...

Страница 20: ...ight fume with an unpleasant odour Open windows Leave the room if the smell is too intense The fume is non toxic and will disappear completely after the unit will have been used a few times at higher...

Страница 21: ...ble 4 2 to adjust the draft control to the desired burn rate Draft Settings Burn Rate Draft Setting Low Push Control to end of travel Medium Low Pull Control by 3 8 from closed position Medium High Pu...

Страница 22: ...burn cleanly without smouldering If the fire smoulders without flame re establish a hotter fire before moving the air control to the lower setting A yellow flame burning in the top of the firebox is a...

Страница 23: ...This may take up to one hour depending on how hot the fire is NOTE ENSURE THE FAN CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE INSERT TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN CORD BENE...

Страница 24: ...quired when burning damp wood and or when burning slow fires Generally if the glass is not staying clean then the unit is being under fired Dirty glass may be self cleaned by burning a hot fire i e dr...

Страница 25: ...ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container unt...

Страница 26: ...e the amount of creosote produced Even so the chimney connector pipe and chimney should be inspected at least once every two months during the heating season to determine if a creosote build up has oc...

Страница 27: ...inside the firebox The EPA output on the other hand is what has been obtained during emissions testing The EPA test procedure requires that a special type of wood be used and positioned inside the fir...

Страница 28: ...ent part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspecti...

Страница 29: ...NUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD INSERT Verified and tested following ULC S628 and UL 1482 Standards by Stove Builder International Inc 250 rue de Copenhague St Augustin...

Страница 30: ...mage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Keep and sa...

Страница 31: ...INSTALLATION INSTRUCTIONS OPTIONAL 12 3 8 BAFFLE INSTALLATION 13 3 9 SECONDARY AIR TUBE REPLACEMENT 14 3 10 REMOVAL INSTRUCTIONS 15 Section 4 0 OPERATION 16 4 1 SAFETY INFORMATION 16 4 2 CORDWOOD FUEL...

Страница 32: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 33: ...manufacturer s specs and code conformity The chimney must be of at least 1 25 mm larger in diameter to accommodate a required continuous stainless steel liner running from the flue collar to the top o...

Страница 34: ...mpensate for poor draft situations caused by large cross sectional chimneys The insert will not work without a positive seal in the chimney Chimneys constructed outside of the home on an exterior wall...

Страница 35: ...to any combustibles as mentioned on your insert certification label See figure 3 1 and table 3 1 Figure 3 1 CLEARANCES MINIMUM MASONRY OPENING A 13 330 mm F 24 610 mm B 22 559 mm G 29 737 mm C 10 254...

Страница 36: ...front of the insert is included in the calculation of the floor protector s dimensions Convert specification to R value k factor is given with a required thickness T in inches R 1 k x T C factor is g...

Страница 37: ...um floor protection for combustible floor materials as specified in this manual Floor protection to the front is to be measured from the fuel loading door opening 5 Osburn recommends that you install...

Страница 38: ...he room This creates a potential health hazard 3 CONNECTOR INSTALLATION A flue connector may provide acceptable performance however we recommend the use of a chimney liner to ensure satisfactory perfo...

Страница 39: ...inished side down on a flat soft non abrasive surface 2 Assemble the faceplate trim attaching the mitered corners with the corner brackets see Figure 3 5 3 Line up the holes of the side and top panels...

Страница 40: ...lay see Figure 3 7 Figure 3 7 2 Flip over both parts with the finished side on a plane and smooth surface free from dirt to avoid any scratches Align the holes of the door to those of the overlay Fix...

Страница 41: ...Open the rectangular outlet on the side of the unit by gently removing the material held in place by micro joints Use pliers Note The fresh air intake may be installed on the right or left end side o...

Страница 42: ...any damaged firebricks replaced Check the firebricks annually for damage and replace if they are broken or damaged See Figure 3 8 and 3 9 for the firebrick layout Install the side back firebricks firs...

Страница 43: ...r using a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baffle Importan...

Страница 44: ...ur insert Unscrew the faceplate fastener holding the faceplate to the faceplate extension Remove faceplate by pulling on it Remove faceplate extension Unclip the blower assembly Remove the three screw...

Страница 45: ...spillage or a back draft causing flame or smoke to spill into the room 5 Never use gasoline type lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or freshen a fire...

Страница 46: ...this is not done it could cause poor air quality in the home poor and incomplete combustion and poor efficiency in the insert Adequate ventilation is required to reduce effects from room air starvatio...

Страница 47: ...moisture content of 20 or less are ideal Dry seasoned wood can be distinguished from green wood by the checks or cracks in the ends 4 Wet or green wood will tend to cause the fire to smoulder produci...

Страница 48: ...ight fume with an unpleasant odour Open windows Leave the room if the smell is too intense The fume is non toxic and will disappear completely after the unit will have been used a few times at higher...

Страница 49: ...ble 4 2 to adjust the draft control to the desired burn rate Draft Settings Burn Rate Draft Setting Low Push Control to end of travel Medium Low Pull Control by 3 8 from closed position Medium High Pu...

Страница 50: ...burn cleanly without smouldering If the fire smoulders without flame re establish a hotter fire before moving the air control to the lower setting A yellow flame burning in the top of the firebox is a...

Страница 51: ...This may take up to one hour depending on how hot the fire is NOTE ENSURE THE FAN CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE INSERT TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN CORD BENE...

Страница 52: ...quired when burning damp wood and or when burning slow fires Generally if the glass is not staying clean then the unit is being under fired Dirty glass may be self cleaned by burning a hot fire i e dr...

Страница 53: ...ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container unt...

Страница 54: ...e the amount of creosote produced Even so the chimney connector pipe and chimney should be inspected at least once every two months during the heating season to determine if a creosote build up has oc...

Страница 55: ...inside the firebox The EPA output on the other hand is what has been obtained during emissions testing The EPA test procedure requires that a special type of wood be used and positioned inside the fir...

Страница 56: ...ent part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspecti...

Страница 57: ...NUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD INSERT Verified and tested following ULC S628 and UL 1482 Standards by Stove Builder International Inc 250 rue de Copenhague St Augustin...

Страница 58: ...mage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Keep and sa...

Страница 59: ...INSTALLATION INSTRUCTIONS OPTIONAL 12 3 8 BAFFLE INSTALLATION 13 3 9 SECONDARY AIR TUBE REPLACEMENT 14 3 10 REMOVAL INSTRUCTIONS 15 Section 4 0 OPERATION 16 4 1 SAFETY INFORMATION 16 4 2 CORDWOOD FUEL...

Страница 60: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 61: ...manufacturer s specs and code conformity The chimney must be of at least 1 25 mm larger in diameter to accommodate a required continuous stainless steel liner running from the flue collar to the top o...

Страница 62: ...mpensate for poor draft situations caused by large cross sectional chimneys The insert will not work without a positive seal in the chimney Chimneys constructed outside of the home on an exterior wall...

Страница 63: ...to any combustibles as mentioned on your insert certification label See figure 3 1 and table 3 1 Figure 3 1 CLEARANCES MINIMUM MASONRY OPENING A 13 330 mm F 24 610 mm B 22 559 mm G 29 737 mm C 10 254...

Страница 64: ...front of the insert is included in the calculation of the floor protector s dimensions Convert specification to R value k factor is given with a required thickness T in inches R 1 k x T C factor is g...

Страница 65: ...um floor protection for combustible floor materials as specified in this manual Floor protection to the front is to be measured from the fuel loading door opening 5 Osburn recommends that you install...

Страница 66: ...he room This creates a potential health hazard 3 CONNECTOR INSTALLATION A flue connector may provide acceptable performance however we recommend the use of a chimney liner to ensure satisfactory perfo...

Страница 67: ...inished side down on a flat soft non abrasive surface 2 Assemble the faceplate trim attaching the mitered corners with the corner brackets see Figure 3 5 3 Line up the holes of the side and top panels...

Страница 68: ...lay see Figure 3 7 Figure 3 7 2 Flip over both parts with the finished side on a plane and smooth surface free from dirt to avoid any scratches Align the holes of the door to those of the overlay Fix...

Страница 69: ...Open the rectangular outlet on the side of the unit by gently removing the material held in place by micro joints Use pliers Note The fresh air intake may be installed on the right or left end side o...

Страница 70: ...any damaged firebricks replaced Check the firebricks annually for damage and replace if they are broken or damaged See Figure 3 8 and 3 9 for the firebrick layout Install the side back firebricks firs...

Страница 71: ...r using a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baffle Importan...

Страница 72: ...ur insert Unscrew the faceplate fastener holding the faceplate to the faceplate extension Remove faceplate by pulling on it Remove faceplate extension Unclip the blower assembly Remove the three screw...

Страница 73: ...spillage or a back draft causing flame or smoke to spill into the room 5 Never use gasoline type lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or freshen a fire...

Страница 74: ...this is not done it could cause poor air quality in the home poor and incomplete combustion and poor efficiency in the insert Adequate ventilation is required to reduce effects from room air starvatio...

Страница 75: ...moisture content of 20 or less are ideal Dry seasoned wood can be distinguished from green wood by the checks or cracks in the ends 4 Wet or green wood will tend to cause the fire to smoulder produci...

Страница 76: ...ight fume with an unpleasant odour Open windows Leave the room if the smell is too intense The fume is non toxic and will disappear completely after the unit will have been used a few times at higher...

Страница 77: ...ble 4 2 to adjust the draft control to the desired burn rate Draft Settings Burn Rate Draft Setting Low Push Control to end of travel Medium Low Pull Control by 3 8 from closed position Medium High Pu...

Страница 78: ...burn cleanly without smouldering If the fire smoulders without flame re establish a hotter fire before moving the air control to the lower setting A yellow flame burning in the top of the firebox is a...

Страница 79: ...This may take up to one hour depending on how hot the fire is NOTE ENSURE THE FAN CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE INSERT TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN CORD BENE...

Страница 80: ...quired when burning damp wood and or when burning slow fires Generally if the glass is not staying clean then the unit is being under fired Dirty glass may be self cleaned by burning a hot fire i e dr...

Страница 81: ...ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container unt...

Страница 82: ...e the amount of creosote produced Even so the chimney connector pipe and chimney should be inspected at least once every two months during the heating season to determine if a creosote build up has oc...

Страница 83: ...inside the firebox The EPA output on the other hand is what has been obtained during emissions testing The EPA test procedure requires that a special type of wood be used and positioned inside the fir...

Страница 84: ...ent part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspecti...

Страница 85: ...NUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD INSERT Verified and tested following ULC S628 and UL 1482 Standards by Stove Builder International Inc 250 rue de Copenhague St Augustin...

Страница 86: ...mage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Keep and sa...

Страница 87: ...INSTALLATION INSTRUCTIONS OPTIONAL 12 3 8 BAFFLE INSTALLATION 13 3 9 SECONDARY AIR TUBE REPLACEMENT 14 3 10 REMOVAL INSTRUCTIONS 15 Section 4 0 OPERATION 16 4 1 SAFETY INFORMATION 16 4 2 CORDWOOD FUEL...

Страница 88: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 89: ...manufacturer s specs and code conformity The chimney must be of at least 1 25 mm larger in diameter to accommodate a required continuous stainless steel liner running from the flue collar to the top o...

Страница 90: ...mpensate for poor draft situations caused by large cross sectional chimneys The insert will not work without a positive seal in the chimney Chimneys constructed outside of the home on an exterior wall...

Страница 91: ...to any combustibles as mentioned on your insert certification label See figure 3 1 and table 3 1 Figure 3 1 CLEARANCES MINIMUM MASONRY OPENING A 13 330 mm F 24 610 mm B 22 559 mm G 29 737 mm C 10 254...

Страница 92: ...front of the insert is included in the calculation of the floor protector s dimensions Convert specification to R value k factor is given with a required thickness T in inches R 1 k x T C factor is g...

Страница 93: ...um floor protection for combustible floor materials as specified in this manual Floor protection to the front is to be measured from the fuel loading door opening 5 Osburn recommends that you install...

Страница 94: ...he room This creates a potential health hazard 3 CONNECTOR INSTALLATION A flue connector may provide acceptable performance however we recommend the use of a chimney liner to ensure satisfactory perfo...

Страница 95: ...inished side down on a flat soft non abrasive surface 2 Assemble the faceplate trim attaching the mitered corners with the corner brackets see Figure 3 5 3 Line up the holes of the side and top panels...

Страница 96: ...lay see Figure 3 7 Figure 3 7 2 Flip over both parts with the finished side on a plane and smooth surface free from dirt to avoid any scratches Align the holes of the door to those of the overlay Fix...

Страница 97: ...Open the rectangular outlet on the side of the unit by gently removing the material held in place by micro joints Use pliers Note The fresh air intake may be installed on the right or left end side o...

Страница 98: ...any damaged firebricks replaced Check the firebricks annually for damage and replace if they are broken or damaged See Figure 3 8 and 3 9 for the firebrick layout Install the side back firebricks firs...

Страница 99: ...r using a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baffle Importan...

Страница 100: ...ur insert Unscrew the faceplate fastener holding the faceplate to the faceplate extension Remove faceplate by pulling on it Remove faceplate extension Unclip the blower assembly Remove the three screw...

Страница 101: ...spillage or a back draft causing flame or smoke to spill into the room 5 Never use gasoline type lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or freshen a fire...

Страница 102: ...this is not done it could cause poor air quality in the home poor and incomplete combustion and poor efficiency in the insert Adequate ventilation is required to reduce effects from room air starvatio...

Страница 103: ...moisture content of 20 or less are ideal Dry seasoned wood can be distinguished from green wood by the checks or cracks in the ends 4 Wet or green wood will tend to cause the fire to smoulder produci...

Страница 104: ...ight fume with an unpleasant odour Open windows Leave the room if the smell is too intense The fume is non toxic and will disappear completely after the unit will have been used a few times at higher...

Страница 105: ...ble 4 2 to adjust the draft control to the desired burn rate Draft Settings Burn Rate Draft Setting Low Push Control to end of travel Medium Low Pull Control by 3 8 from closed position Medium High Pu...

Страница 106: ...burn cleanly without smouldering If the fire smoulders without flame re establish a hotter fire before moving the air control to the lower setting A yellow flame burning in the top of the firebox is a...

Страница 107: ...This may take up to one hour depending on how hot the fire is NOTE ENSURE THE FAN CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE INSERT TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN CORD BENE...

Страница 108: ...quired when burning damp wood and or when burning slow fires Generally if the glass is not staying clean then the unit is being under fired Dirty glass may be self cleaned by burning a hot fire i e dr...

Страница 109: ...ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container unt...

Страница 110: ...e the amount of creosote produced Even so the chimney connector pipe and chimney should be inspected at least once every two months during the heating season to determine if a creosote build up has oc...

Страница 111: ...inside the firebox The EPA output on the other hand is what has been obtained during emissions testing The EPA test procedure requires that a special type of wood be used and positioned inside the fir...

Страница 112: ...ent part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspecti...

Страница 113: ...NUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD INSERT Verified and tested following ULC S628 and UL 1482 Standards by Stove Builder International Inc 250 rue de Copenhague St Augustin...

Страница 114: ...mage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Keep and sa...

Страница 115: ...INSTALLATION INSTRUCTIONS OPTIONAL 12 3 8 BAFFLE INSTALLATION 13 3 9 SECONDARY AIR TUBE REPLACEMENT 14 3 10 REMOVAL INSTRUCTIONS 15 Section 4 0 OPERATION 16 4 1 SAFETY INFORMATION 16 4 2 CORDWOOD FUEL...

Страница 116: ...3 Section 1 0 DIMENSIONS Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 117: ...manufacturer s specs and code conformity The chimney must be of at least 1 25 mm larger in diameter to accommodate a required continuous stainless steel liner running from the flue collar to the top o...

Страница 118: ...mpensate for poor draft situations caused by large cross sectional chimneys The insert will not work without a positive seal in the chimney Chimneys constructed outside of the home on an exterior wall...

Страница 119: ...to any combustibles as mentioned on your insert certification label See figure 3 1 and table 3 1 Figure 3 1 CLEARANCES MINIMUM MASONRY OPENING A 13 330 mm F 24 610 mm B 22 559 mm G 29 737 mm C 10 254...

Страница 120: ...front of the insert is included in the calculation of the floor protector s dimensions Convert specification to R value k factor is given with a required thickness T in inches R 1 k x T C factor is g...

Страница 121: ...um floor protection for combustible floor materials as specified in this manual Floor protection to the front is to be measured from the fuel loading door opening 5 Osburn recommends that you install...

Страница 122: ...he room This creates a potential health hazard 3 CONNECTOR INSTALLATION A flue connector may provide acceptable performance however we recommend the use of a chimney liner to ensure satisfactory perfo...

Страница 123: ...inished side down on a flat soft non abrasive surface 2 Assemble the faceplate trim attaching the mitered corners with the corner brackets see Figure 3 5 3 Line up the holes of the side and top panels...

Страница 124: ...lay see Figure 3 7 Figure 3 7 2 Flip over both parts with the finished side on a plane and smooth surface free from dirt to avoid any scratches Align the holes of the door to those of the overlay Fix...

Страница 125: ...Open the rectangular outlet on the side of the unit by gently removing the material held in place by micro joints Use pliers Note The fresh air intake may be installed on the right or left end side o...

Страница 126: ...any damaged firebricks replaced Check the firebricks annually for damage and replace if they are broken or damaged See Figure 3 8 and 3 9 for the firebrick layout Install the side back firebricks firs...

Страница 127: ...r using a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baffle Importan...

Страница 128: ...ur insert Unscrew the faceplate fastener holding the faceplate to the faceplate extension Remove faceplate by pulling on it Remove faceplate extension Unclip the blower assembly Remove the three screw...

Страница 129: ...spillage or a back draft causing flame or smoke to spill into the room 5 Never use gasoline type lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or freshen a fire...

Страница 130: ...this is not done it could cause poor air quality in the home poor and incomplete combustion and poor efficiency in the insert Adequate ventilation is required to reduce effects from room air starvatio...

Страница 131: ...moisture content of 20 or less are ideal Dry seasoned wood can be distinguished from green wood by the checks or cracks in the ends 4 Wet or green wood will tend to cause the fire to smoulder produci...

Страница 132: ...ight fume with an unpleasant odour Open windows Leave the room if the smell is too intense The fume is non toxic and will disappear completely after the unit will have been used a few times at higher...

Страница 133: ...ble 4 2 to adjust the draft control to the desired burn rate Draft Settings Burn Rate Draft Setting Low Push Control to end of travel Medium Low Pull Control by 3 8 from closed position Medium High Pu...

Страница 134: ...burn cleanly without smouldering If the fire smoulders without flame re establish a hotter fire before moving the air control to the lower setting A yellow flame burning in the top of the firebox is a...

Страница 135: ...This may take up to one hour depending on how hot the fire is NOTE ENSURE THE FAN CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE INSERT TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN CORD BENE...

Страница 136: ...quired when burning damp wood and or when burning slow fires Generally if the glass is not staying clean then the unit is being under fired Dirty glass may be self cleaned by burning a hot fire i e dr...

Страница 137: ...ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container unt...

Страница 138: ...e the amount of creosote produced Even so the chimney connector pipe and chimney should be inspected at least once every two months during the heating season to determine if a creosote build up has oc...

Страница 139: ...inside the firebox The EPA output on the other hand is what has been obtained during emissions testing The EPA test procedure requires that a special type of wood be used and positioned inside the fir...

Страница 140: ...ent part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspecti...

Отзывы: