2.5 - 

RESET THE FACTORY SETTINGS OF THE PARAMETERS

 

The  B4U  allows  you  to  reset  the  parameters  to  the  factory  default 
values. 

To return to the factory values or default values of the parameters, it 
is  enough  to  activate  the  password  protection  and  once  activated 
when the display reads "rP" enter the password -48

Once  the  password  has  been  confirmed  with  the  LIGHT  key,  the 
display will show "---" for 2 seconds when the equipment resets the 
parameters, does a little test and sets all the parameters to default 
values. 
 

 
2.6 - KEYBOARD LOCK FUNCTION 

The B4U can fully lock the keyboard.  
Such a function is useful when the controller is exposed to the public 
and you want to prevent tampering

The  key  lock  function  can  be  activated  by  programming  the  “Lo” 
parameter to any value other than oF.  

The value configured in the "Lo" parameter is t

ime that if the keyboard 

remains untouched, the keyboard is fully locked automatically

Therefore if we do not press any key during the time 

"It"

the B4U will 

automatically lock out normal keyboard operation.  

When you press any key when the keypad is locked, the display will 
show "Ln" to indicate that the lock is active. 
To unlock the keyboard, we must press the LIGHT key for 8 seconds, 
after that time the display will show "LF" and all the key functions will 
be operational again. 
 

2.7 - DISPLAY OF THE VARIABLES 

The  display  normally  shows  the  variable  configured  in  the  "dS" 
parameter,  but  it  is  possible  to  show  all  the  measurement  and 
operating  variables  by  simultaneously  pressing  the  ON  /  OFF  + 
DOWN  keys  for  5  seconds.  The  screen  will  alternately  show  the 
initials that identify the first variable and its value. 
With the UP or DOWN keys, we can see all the variables: 
"P1" - Pr1 probe measurement 
"P2" - Pr2 probe measurement 
"P3" - Pr3 probe measurement 
"Lt" - Minimum stored temperature Pr1 
"Ht" - Maximum stored Pr1 temperature. 
If the function related to the power supply voltage alarms is enabled 
(parameter "LU" or "HU" different from oF), the variable P5 will also 
appear. 
The  maximum  values  Lt  and  Ht  will  not  be  saved  when  the  power 
supply  fails  and  can  be  reset  by  pressing  the  ON  /  OFF  key  for  3 
seconds  during the maximum  display.  After  3  seconds,  the  display 
will  show  "---"  for  an  instant  to  indicate  that  the  cancellation  has 
occurred  and  will  assume  the  maximum  temperature  measured  at 
that instant. 
To exit the variables display mode, we will not press any of the 4 keys 
for approximately 10 seconds. 
 
 
 

3 - WARNINGS FOR USE 

 
3.1 - PERMITTED USE

 

The B4U has been designed as a measuring and regulating device 
in  accordance  with  EN  60730-1  for  operation  at  altitudes  up  to 
2000m.  
The use of the B4U in applications not expressly provided for in the 
aforementioned  standard  must  include  all  appropriate  protection 
measures. 

The  B4U  must  be  adequately  protected  and  out  of  the  reach  of 
liquids, dust, grease and dirt. It must be accessible only with the use 
of a secure tool or system (except the front one).

  

The  B4U  CANNOT  be  used  in  environments  with  a  dangerous 

atmosphere (flammable or explosive) without adequate 
protection.  
If used with the NTC probe that is supplied together with 
the  B4U,  it  will  comply  with  the  EN  13485  standard 

("Thermometers to measure the temperature of air and products for 
the  transport,  storage  and  distribution  of  refrigerated,  frozen  and 
frozen food products") with the following designation: [air, S, A, 2,  - 
50 ° C .. + 90 ° C]. 
Remember  that  the  B4U,  when  in  operation,  must  be  periodically 
checked by the end user in accordance with the EN 13486 standard. 

It is recalled that the installer must ensure that the standard regarding 
electromagnetic  compatibility  is  respected  after  the  implementation 
in the installation of the equipment, possibly using suitable filters.

.  

In  case  of  failure  or  malfunction  of  the  B4U  that  could  create 
dangerous situations or damage to people, things, animals or product 
(defrosting of food or changes in its ideal state), it is recalled that the 
installation  should  be  equipped  with  additional  electronic  or 
electromechanical devices to guarantee the security.

 

 
 

4 - INSTALLATION WARNINGS 

 
4.1 - MECHANICAL ASSEMBLY 

The POWER UNIT B4U module is designed for installation with fixing 
by 2 screws. 
The  DISPLAY  B4U  panel,  with  dimensions  of  96  x  50  mm,  is 
designed to be paneled. 
A 90 x 44 mm hole must be made and the DISPLAY B4U must be 
inserted, fixing it with the special supports provided. 
Avoid placing the B4U module in places exposed to high humidity or 
dirt  that  may  cause  condensation  or  the  introduction  of  conductive 
parts or substances. 
Make sure the B4U has adequate ventilation and avoid installation in 
containers  where  other  devices  are  installed  that  can  cause  the 
devices to operate outside of the set temperature limits. 
Install the devices as far as possible from sources that can generate 
electromagnetic  disturbances  such  as  motors,  contactors,  relays, 
solenoid valves, etc. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание B4U

Страница 1: ...ONNECTION 5 FUNCTIONING 5 1 ON STAND BY FUNCTION 5 2 NORMAL ECONOMIC AND TURBO OPERATING MODES 5 3 PROBE INPUTS AND DISPLAY CONFIGURATION 5 4 DIGITAL INPUTS CONFIGURATION 5 5 CONFIGURATION OF THE OUTPUTS AND BUZZER 5 6 TEMPERATURE REGULATION 5 7 COMPRESSOR PROTECTION AND START DELAY FUNCTION 5 8 DEFROST CONTROL 5 8 1 AUTOMATIC DEFROST 5 8 2 MANUAL DEFROST 5 8 3 DEFROST END 5 8 4 INTERVAL AND DURAT...

Страница 2: ...be configured 3 DOWN AUX 2 key In normal operating mode pressing and releasing allows quick access to the Set Point selection and modification mode Pressing for 3 seconds allows activating deactivating the configured output configured as A2 anti fog heating elements In the programming and display modes of the temperature measured by the room probe the evaporator temperature P1 and P2 and in additi...

Страница 3: ...the PP parameter within the tS group To have this protection available we will program the desired password number in the PP parameter Once the protection is activated to access the parameter menu press the ON OFF LIGHT keys simultaneously for 5 seconds and the display will show rP press the LIGHT key and the display will show 0 At this point using the UP and DOWN keys we will establish the passwo...

Страница 4: ...hat instant To exit the variables display mode we will not press any of the 4 keys for approximately 10 seconds 3 WARNINGS FOR USE 3 1 PERMITTED USE The B4U has been designed as a measuring and regulating device in accordance with EN 60730 1 for operation at altitudes up to 2000m The use of the B4U in applications not expressly provided for in the aforementioned standard must include all appropria...

Страница 5: ...eople things or animals 4 2 1 ELECTRICAL WIRING DIAGRAM Color legend Cable Strip 1 Brown 2 White 3 Green 4 Blue 5 Red 6 Black 5 OPERATION 5 1 ON STAND BY FUNCTION The B4U once turned on can take 2 different conditions ON It means that it works with the normal control functions STAND BY It means that the controller does not operate with any control function and the display turns off the Stand by LE...

Страница 6: ...g the Et time it will automatically switch to ECONOMY mode The B4U remains in ECONOMY mode until the door is reopened or if configured until the tt timeout When it exits the ECONOMY mode the B4U performs a TURBO cycle to recover the temperature of the products then returns to the NORMAL operating mode and so on 1 The time Et is reset every time the door is opened In the case of the example the doo...

Страница 7: ...ATION OF THE OUTPUTS AND BUZZER The parameters related to the configuration of the outputs are contained in the group Ou The outputs of the B4U can be configured through the parameters o1 o2 o3 and o4 with the following functions ot Compressor Solenoid Control or Cooling Element dF Control of defrost heaters Fn Evaporator fans control Au Auxiliary output control En Allows the Control of a silencea...

Страница 8: ...with Heating action In this case the regulation Set point for the ot output will be SP SE SH while for the HE output it is through the Set SH The regulation differential for the ot output is the active one between d or Ed or Hd is assumed automatically by the B4U to have positive values in the cooling action while for the HE output the differential will be Hd considered with negative values during...

Страница 9: ...counts the time since the B4U was started This mode is the one currently used in refrigeration systems ct At intervals of compressor operation time The interval di is counted as the sum of the operating times of the output ot output on This mode is normally used in refrigeration systems with compressor stop in defrost cS Defrost cycle at each compressor stop The regulator starts a defrost cycle ev...

Страница 10: ...be set as EP exceeds the temperature set in parameter tE If this temperature is not reached within the time set in parameter dE the defrost will be interrupted To avoid unnecessary defrosting when the evaporator temperature is high the tS parameter allows setting the temperature referring to the evaporator probe below which the defrosts will be activated Therefore in the indicated modes if the tem...

Страница 11: ...nfigured with the o1 o2 o3 o4 parameters The buzzer can be configured to signal alarms by setting the parameter Bu 1 or 3 or 4 and always functions as an alarm that can be silenced This means that when activated it can be deactivated by briefly pressing any key Alarms can be configured to signal them by configuring the outputs The possible alarms that can be configured are the following On When yo...

Страница 12: ...e to show the initials oP on the display When the door open alarm intervenes the normally activated outputs fans or fans compressor are also deactivated 5 10 4 VOLTAGE CONTROL ALARM The parameters related to the voltage control alarm functions are found in the UA folder The B4U can automatically deactivate the control outputs when the mains voltage measured by the B4U through its power supply is l...

Страница 13: ...e SP S Parameters Relative to the Set Point 1 SH Turbo Set Point or Minimum Set point and Superheat Set point in HC mode 99 HS 4 0 2 SE Economic Set Point maximum set point LS 99 8 0 3 S1 Set Point SE SH 4 0 In i Parameters related to inputs 4 uP Measurement unit and resolution decimal point C0 C with resolution 1 F0 F with 1 resolution C1 C with 0 1 resolution F1 F with 0 1 resolution C0 F0 C1 F1...

Страница 14: ... 0 29 Ei Interval between defrosts in case of evaporator probe error oF 01 59 min 01 99 hrs 4 30 EE Defrost duration in case of evaporator probe error oF 01 59 sec 01 99 min 20 31 tS Temperature from which the defrost starts 99 9 9 9 9 10 99 C F 2 0 32 tF Temperature that forces the start of the evaporator defrost 99 9 9 9 9 10 99 C F 99 33 St Defrost start delay due to evaporator temperature oF 0...

Страница 15: ...1 2Y Temperature alarm type 2 see 1y 1 2 3 4 5 6 7 8 9 10 3 62 2H High temperature alarm setpoint 2 99 9 9 9 9 10 99 C F oF 63 2L Low temperature alarm setpoint 2 99 9 9 9 9 10 99 C F oF 64 2d 2H and 2L alarm hysteresis 0 0 9 9 30 C F 1 0 65 2t Alarm delay 2H and 2L oF 01 59 sec 01 99 min oF 66 2P Temperature alarm delay time 2 on connection oF 01 59 min 01 99 hrs 2 67 2A Action of alarms 2 on the...

Страница 16: ...ify the correct functioning of the probe it is useful to have the ohm values of the probes EP Possible anomaly in the EEPROM memory Press the SET key Turn the device off and on Err Fatal Device Memory Error Replace the device or send it in for possible repair 7 2 CLEANING It is recommended to clean the B4U only with a cloth slightly dampened with water or a non abrasive detergent and that does not...

Страница 17: ...MATE N LOK 250 removable connector Connection Display B4U Power Unit B4U 3 m MAX Through the cable with removable mini connectors Pollution degree 2 Ambient operating temperature 0 60 C Operating ambient humidity less than 95 RH non condensing Transport and storage temperature 25 60 C 8 3 FUNCTIONAL CHARACTERISTICS Temperature control ON OFF Defrost control by intervals or by temperature with elec...

Отзывы: