1. Purpose
The PIR-R detector (hereinafter referred to as the “detector”) is designed to detect a penetra-
tion into the internal space of protected objects and transmit this events to the Lun-R receiver that
is connected to the Lun control panel (more about for compatibility, see the documentation of the
relevant control panel).
Product is not equipped with built-in cameras and microphones, devices and units for
hidden video and audio recording.
2. Safety Precautions
Only the employees, familiar with the module design, instructed on the safety arrangements
shall be allowed to install, routinely maintain and repair.
The device does not have open live parts, representing the danger of electric shock to a per-
son. No safety ground.
3. Technical specifications
The detector technical characteristics is shown in the Table 1.
Table 1. Technical characteristics
Characteristic
Value
Operating frequency range (depends of modification), MHz
433.05…434.79 or
868.70…869.20
Power radiated by the transmitter, mW
up to 10
The health test signals period, seconds
60
Detection zone size, m
10*10
Range, m
10
Detectable speeds range, m/s
0.3…3
Power source type
CR123A battery
Battery voltage, V
2.2…3.2
The battery predicted service life, years
up to 8
Degree of protection provided by enclosure
IP41
Dimensions, mm
90*60*50
Weight, g
100
PIR-R
Version en_2
3