The detector design provides protection against insects from entering the housing.

When the communication loss with the receiver, the detector continues to search it. Therefore,

when you turn off the receiver or control panel for a long time, it is recommended to remove the

detector’s battery.

4.1. Modes Indication

The detector modes displays by multicolored LED:

Norm

 – light off;

Alarm

 – flashing red once every 4 seconds – upon the moving people or large animals

(see section 4) are detected. This flashing will operate up to 15 minutes after the detec-

tor’s cover is closed then flashing stops to conserve the battery;

Binding

 – blinking green while waiting for a signal from the Lun-R receiver to register in

the control panel memory;

Bound

 – when the binding is completed successfully – turning on red for 2…3 seconds.

4.2. Binding

A new detector must be bound to the control panel in order to successfully transmit its com-

mands to the receiver.

To register a detector, do the following:

1. In the control panel configuration, pre-set the required number of radiozones, their type,

group membership and other parameters;

2. Turn on the control panel in the operating mode and  switch to  the desired control

panel’s group;

3. Switch the control panel to the wireless detectors binding mode (see the corresponding

control panel programming manual);

4. Install the battery to the detector observing polarity;
5. Switch the detector to the binding mode by short-circuit the 

RESET

 contacts for 2…3 sec-

onds (until the blinking green – the signal "

Binding

");

6. Binding will processed automatically and, if successful, ends by turning on the red LED

for 2…3 seconds (signal "

Bound

").

The detector waits 70 seconds for binding. To reinitialize the binding process, briefly close the

RESET

 contacts again.

4.3. Wireless signal strength

The detector should be in the radio visibility zone of its receiver, therefore, after binding, be-

fore installation at the facility, it is strongly recommended to recognize the wireless signal strength.

To do this, turn on and place the detector and the control panel in the intended installation

locations, and then press and release the tamper button. The detector indicators display the wire-

less signal strength as follows:

LED color

Number of blinks

Signal strength

Green

3

Best

2

Good

1

Poor

Red

4

No connection

If the signal strength is poor or there is no connection, it is recommended to change the loca-

tion of the detector and repeat the above process in order to form a reliable reception map.

PIR-R

Version en_2

5

Содержание PIR-R

Страница 1: ...liance with operating modes and conditions therefore this document require ments is mandatory Motion Detector PIR R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiver L...

Страница 2: ...ns 3 3 Technical specifications 3 4 How to use 4 4 1 Modes Indication 5 4 2 Binding 5 4 3 Wireless signal strength 5 4 4 Installing 6 5 Maintenance 6 6 Operating conditions 6 7 Storage 7 8 Transportat...

Страница 3: ...wed to install routinely maintain and repair The device does not have open live parts representing the danger of electric shock to a per son No safety ground 3 Technical specifications The detector te...

Страница 4: ...generated If the housing cover is opened the tamper will be triggered and the tamper alarm event will be generated If the voltage of the battery drops to 2 2V or lower the event Battery low is genera...

Страница 5: ...and switch to the desired control panel s group 3 Switch the control panel to the wireless detectors binding mode see the corresponding control panel programming manual 4 Install the battery to the de...

Страница 6: ...er part of the housing then remove the detector cover with the board and battery 3 Drill holes in the bottom of the housing for mounting the detector on the wall To protect against tearing use at leas...

Страница 7: ...period or insulator must be installed in the battery holder 8 Transportation 1 Detector transportation shall be carried out in the manufacturer s package 2 Detector is allowed to be transported by al...

Страница 8: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io PIR R Version en_2 8...

Отзывы: