orolia.com
EdgeSync Manual rev 1 | 41
Privilege
RO
Read-Only (as specified in PTPMIB)
Auth Protocol
RW
Selection of authorization protocol: MD5 or SHA
(applicable only when adding a new user)
Auth Password
WO
Authorization password – should be at least 8 characters
(applicable only when adding a new user)
Priv Protocol
RW
Selection of privacy protocol: MD5 or SHA
(applicable only when adding a new user)
Priv Password
WO
Privacy password – should be at least 8 characters
(applicable only when adding a new user)
Apply / Clear
Apply Button
WO
Click for selection and settings to be applied to the EdgeSync
Clear Button
WO
Click to clear the latest changes
Table 18 SNMPv3 Options
EdgeSync maintains the list of active SNMPv3 users with the user name and their security level at the
bottom of the webpage.
5.
Command Reference
EdgeSync Basic Commands
The login credentials for accessing EdgeSync CLI shell is admin/admin. This is a list of the available
commands related to the control and monitoring of the EdgeSync. The CLI commands are case
insensitive.
Help Command
help
- After logging in, the user can enter “help” to get a list of commands and descriptions to be
displayed on the command terminal.
History Command
history
- To view the history of previously entered commands, enter “history”.
Quit Command
quit
- To terminate the command session and log out, enter “quit”. Note that, pressing Control-C will
have the same effect as “quit” command.
Show commands
The “show” command can be used to show alarms or clock status.