Ormazabal velatia ekor.bat-200 Скачать руководство пользователя страница 3

3

General Instructions

ekor

.bat-200

Contents 

IG-258-EN, versión 01; 16/11/2018

Contents

1.  Description and main characteristics .......................4

1.1. Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2. Architecture  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.3. Processes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.3.1.  Start-up and battery connection. . . . . . . . . . . . . .4
1.3.2.  Battery charge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.3.3.  Battery discharge and disconnection  . . . . . . . . .5
1.3.4.  Slow test or capacity measurement. . . . . . . . . . .6
1.3.5.  Fast test or Impedance measurement. . . . . . . . .6

2. Characteristics ............................................................7

2.1. 

Electrical characteristics . . . . . . . . . . . . . . . . . . . . . .7

2.2. 

Dielectric strength  . . . . . . . . . . . . . . . . . . . . . . . . . . .7

2.3. 

Service conditions  . . . . . . . . . . . . . . . . . . . . . . . . . . .8

2.4. 

CE Conformity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

3. Tests ............................................................................9

3.1. ekor

.bat-200 battery charger. . . . . . . . . . . . . . . . .9

4. Connections ..............................................................11

4.1. 

Terminal blocks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

4.2. 

LED indications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

4.3. Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4.4. 

Front button (B1)  . . . . . . . . . . . . . . . . . . . . . . . . . . .13

4.5. Earthing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

5.  Web access ................................................................14

6.  Unit configuration ...................................................15

6.1. 

Operating parameters. . . . . . . . . . . . . . . . . . . . . . .15

6.1.1.  Communications parameters. . . . . . . . . . . . . . . .16

7.  Equipment test .........................................................17

7.1. 

Force states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

7.2. 

Hardware test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

8.  On-site intervention procedures ............................18

8.1. 

Battery replacement  . . . . . . . . . . . . . . . . . . . . . . . .18

Содержание velatia ekor.bat-200

Страница 1: ...LIB ekor bat 200 Battery Charger General Instructions IG 258 EN version 02 16 11 2018...

Страница 2: ...ectrical installations Personnel must be fully familiar with the instructions and warnings contained in this manual and in other recommendations of a more general nature which are applicable to the si...

Страница 3: ...t or Impedance measurement 6 2 Characteristics 7 2 1 Electrical characteristics 7 2 2 Dielectric strength 7 2 3 Service conditions 8 2 4 CE Conformity 8 3 Tests 9 3 1 ekor bat 200 battery charger 9 4...

Страница 4: ...ut as shown in the image below 1 Input 2 Output 3 10 kV insulation 4 Phase 5 Neutral 6 AC 7 DC 8 24 48 Vdc 9 0 V 10 Earth 11 Chassis 12 Control 13 Alarms 14 Local signalling 15 Ethernet RS232 Figure 1...

Страница 5: ...ge to vary by each degree centigrade The compensation range is limited between a maximum and minimum temperature comp_tmin and comp_tmax Temperature compensation hab_comp can also be enabled in fast c...

Страница 6: ...ted and no more battery tests are carried out until this alarm is recognised The Battery failure alarm is grouped within the Urgent failure digital output 1 3 5 Fast test or Impedance measurement Thef...

Страница 7: ...nt 20 A Power factor 0 6 Rated power 200 W Maximum power 500 W Output range 48 Vcc 39 60 24 Vcc 18 30 V Table 2 1 Input characteristics The charger has four potential free contacts Parameter Remarks V...

Страница 8: ...requirements RoHS Directive 2002 95 CE Table 2 3 Service conditions For higher altitudes check with Ormazabal for the possible influence on equipment performance 2 4 CE Conformity This product compli...

Страница 9: ...terminals of each unit differential mode 1 kV EN 60255 5 Immunity Level Standard Electrostatic discharge Direct contact mode in metal equipment frames and connectors Level 4 8 kV EN 6100 4 2 Air mode...

Страница 10: ...nt peaks start up at rated power Level to be applied 12 A Mechanical tests Level Standard IP Protection grade Level to be applied IP20 EN 20324 IK Protection grade Level to be applied IK06 EN 50102 Vi...

Страница 11: ...230 Vac rms 2 AC input N phase X2 Alarms 1 Urgent failure alarm NC contact 2 Standalone end alarm NA Contact 3 Power failure alarm NA Contact 4 Non urgent failure alarm NA Contact 5 Alarms common X3...

Страница 12: ...d On Battery test failure end of battery s working life Red Charger ERROR Flashing Anomalies in charger Temperature sensor others On Temperature sensor failure Table 4 2 Description of the indications...

Страница 13: ...button is pressed for more than 3 seconds If there is a battery connected the charge process continues and the battery test failure alarm resets if it is enabled If there is no battery the urgent alar...

Страница 14: ...ETH1 port Access to the charger s webpage is via the ETH1 port both locally and remotely LOCAL IP 100 0 0 1 Remote IP Customised with the requested value Firefox browser version 26 is recommended for...

Страница 15: ...ltage in fast charge V V comp_carga Temperature compensation in fast charge mV C hab_comp Enables temperature compensation in charge 0 NO 1 YES i_flot Battery through current to float mA tlim_carga Ma...

Страница 16: ...esses IP Connexion IP for the SNTP protocol 20 char Gateway Gateway for the SNTP protocol SI_TFALL Time without synchronising in order to consider the internal clock out of sync min T_PETSINCRO Server...

Страница 17: ...oved and all the meters and the state machine restart always maintaining voltage without any interruption in supply 7 2 Hardware test This window can be used to force the state of the luminous indicat...

Страница 18: ...ery alarm is enabled meaning the urgent failure output and the Battery ERROR LED will be enabled 4 Position new batteries and make connections between them 5 Check that battery voltage is between 42 V...

Страница 19: ......

Страница 20: ...Subject to change without prior notice For further information contact Ormazabal Ormazabal Protection Automation IGORRE Spain www ormazabal com...

Отзывы: