TGAP-620-/6620-M12 Series User Manual
ORing Industrial Networking Corp
9
The device can be fixed to the wall. Follow the steps below to install the device on the wall.
Step 1
: Hold the AP upright against the wall
Step 2
: Insert four screws through the large opening of the keyhole-shaped apertures at the
top and bottom of the unit and fasten the screw to the wall with a screwdriver.
Step 3
: Slide the AP downwards and tighten the four screws for added stability.
Instead of screwing the screws in all the way, it is advised to leave a space of
about 2mm to allow room for sliding the AP between the wall and the screws.
3.2 Wiring
For pin assignments of power, console and relay output ports, please refer to the following
tables.
3.2.1
Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the grounding pin on the power connector to the
grounding surface prior to connecting devices.
3.2.2
Power Port Pinouts
The device supports two sets of power supplies and uses the M23 5-pin female connector on
the front panel for the dual power inputs.
Step 1
: Insert a power cable to the power connector on the device.
Step 2
: Rotate the outer ring of the cable connector until a snug
fit is achieved. Make sure
the
connection
is tight.