IGPS-9080 Series User Manual
ORing Industrial Networking Corp
46
received, or when the entry ages out.
TLVs Discarded
Each LLDP frame can contain multiple pieces of information,
known as TLVs (Type Length Value). If a TLV is malformed, it will
be counted and discarded.
TLVs Unrecognized
The number of well-formed TLVs, but with an unknown type value
Org. Discarded
The number of organizationally TLVs received
Age-Outs
Each LLDP frame contains information about how long the LLDP
information is valid (age-out time). If no new LLDP frame is
received during the age-out time, the LLDP information will be
removed, and the value of the age-out counter will be
incremented.
Refresh
Click to refresh the page immediately
Clear
Click to clear the local counters. All counters (including global
counters) are cleared upon reboot.
Auto-refresh
Check to enable an automatic refresh of the page at regular
intervals
5.1.10 Modbus TCP
Modbus TCP uses TCP/IP and Ethernet to carry the data of the Modbus message structure
between compatible devices. The protocol is commonly used in SCADA systems for
communications between a human-machine interface (HMI) and programmable logic
controllers. This page enables you to enable and disable Modbus TCP support of the switch.
Label
Description
Mode
Shows the existing status of the Modbus TCP function
5.1.11 Backup/Restore Configurations
You can save/view or load switch configurations. The configuration file is in XML format.