IGPS-9080 Series User Manual
ORing Industrial Networking Corp
151
PoE turned OFF
: power budget exceeded. The total requested or
used power by the power devices exceeds the maximum power
the power supply can deliver, and port(s) with the lowest priority
will be powered down.
No PD detected
: no power devices detected on the port
PoE turned OFF
: power devices overload. The power devices
have requested or used more power than the port can deliver, and
the port is powered down.
PoE turned OFF
: the power device is turned off.
Invalid PD
: the power device is detected, but is not working
correctly.
5.13 Troubleshooting
5.13.1 Factory Defaults
This function is to force the switch back to the original factory settings. To reset the switch,
select
Reset to Factory Defaults
from the drop-down list and click
Yes
. Only the IP
configuration is retained.
Label
Description
Yes
Click to reset the configuration to factory defaults
No
Click to return to the Port State page without resetting
5.13.2 System Reboot
You can reset the stack switch on this page. After reset, the system will boot normally as if you
have powered on the devices
.