The IES-3080 / IES-3062 SERIES switches support auto MDI/MDI-X operation. You
can use a straight-through cable to connect PC to switch. The following table below
shows the 10BASE-T/ 100BASE-TX MDI and MDI-X port pin outs.
10/100 Base-TX MDI/MDI-X pins assignment
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
Note:
“+” and “-” signs represent the polarity of the wires that make up each wire pair.
4.2 Console Cable
IES-3080 / IES-3062 SERIES switches can be management by console port. The DB-9 to
RJ-45 cable can be found in the package. You can connect them to PC via a RS-232 cable
with DB-9 female connector and the other end (RJ-45 connector) connects to console port of
switch.
PC pin out (male) assignment
RS-232 with DB9 female connector
DB9 to RJ 45
Pin #2 RD
Pin #2 TD
Pin #2
Pin #3 TD
Pin #3 RD
Pin #3
Pin #5 GD
Pin #5 GD
Pin #5