Label
Description
Port Alias
Enter the COM port number that modem is connected to
Interface
Choose an interface for your serial device. Available interfaces
include
RS-232,
RS-422,
RS-485(2-wires),
and
RS-485(4-wires),
Baud Rate
Choose a baud rate in the range between 110 bps and 460800
bps.
Data Bits
Choose the number of data bits to transmit. You can
configure data bits to be 5, 6, 7, or 8. Data is transmitted as a
series of five, six, seven, or eight bits (five and six bit data
formats are used rarely for specialized communications
equipment).
Stop Bits
Choose the number of bits used to indicate the end of a byte. You
can configure stop bits to be 1 or 2(1.5). If Stop Bits is 1.5, the
stop bit is transferred for 150% of the normal time used to
transfer one bit. Both the computer and the peripheral device
must be configured to transmit the same number of stop bits.
Parity
Chose the method of detecting errors in transmission. Parity