Port Profile
Label
Description
Local TCP Port
The TCP port the device uses to listen to connections, and that
other devices must use to contact the device. To avoid conflicts
with well known TCP ports, the default is set to 4000.
Flush Data Buffer After
The received data will be queuing in the buffer until all the
delimiters are matched. When the buffer is full (4K Bytes) or
after "
flush S2E data buffer
" timeout the data will also be
sent. You can set the time from 0 to 65535 seconds.
Delimiter
For advanced data packing options, you can specify
delimiters for
Serial to Ethernet
and / or
Ethernet to Serial
communications. You can define max. 4 delimiters (00~FF,
Hex) for each way. The data will be hold until the delimiters
are received or the option
Flush Serial to Ethernet data
buffer
times out.
0
means disable. Factory default is
0
.
Service Mode - Virtual COM Mode
In Virtual COM Mode, the driver establishes a transparent connection between the host and
the serial device by mapping the port of the serial server to a local COM port on the host
computer. Virtual COM Mode also supports up to 5 simultaneous connections, so that multiple