IDS-4312(+) Series User Manual
ORing Industrial Networking Corp
25
Label
Description
Data Port
Set the port number for data transmission.
Idle Timeout
When a serial port stops data transmission for a defined
period of time (Idle Timeout), the connection will be closed
and the port will be freed and try to connect with other hosts.
0
means the function is disabled which is also the factory
default value. If multilink is configured, only the first host
connection is effective for this setting.
Alive Check
The serial device will send a TCP alive-check package in
each defined time interval (Alive Check) to remote host to
check the the status of TCP connections. If the TCP
connection is not alive, the connection will be closed and the
port will be freed.
0
means the function is disabled which is
also the factory default value.
Max Connection
The number of max connections can be supported
simultaneously is
5
; the default value is
1
.
Map Virtual COM
Select a Virtual COM name to map on.