6 Monitor mode
−
17
−
Present warning
When a warning generates, a corresponding warning code will be displayed.
You can also check or clear warning records.
Note
Do not turn off the driver power while warning records are being cleared (= while the
display is blinking). Doing so may damage the data.
•
How to check a warning record
You can check up to ten most recent warnings, starting from the latest one.
1.
While a warning is displayed, press the
key to move to the lower level.
The latest warning is displayed.
2.
Press the
key.
The second latest warning is displayed.
3.
Every time the
key is pressed, the next older warning will be displayed. Use the
keys to select the warning record you want to check.
•
How to clear all warning records
You can clear all warning records at once.
1.
While a warning is displayed, press the
key to move to the lower level.
2.
Press the
key and select the warning record clear screen.
3.
Press the
key.
All warning records are cleared.
Note
You can also clear the warning records by turning off the driver power.
Warning record 1 (latest)
Present warning
Warning record 1 (latest)
Warning record 2
Warning record 10
(oldest)
Clear warning records
Warning records are being
cleared (blinking display)
to navigate
Use
through the items.
∗
If operations are limited by the edit lock function (p.7), the screen text in gray is not shown.
Warning code list
Code
Warning name
Code
Warning name
10 Overflow
22 Overvoltage
21
Overheat
84
RS-485 communication error