![Orientalmotor BXII Series Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/orientalmotor/bxii-series/bxii-series_operating-manual_1651190045.webp)
Parameter
−45−
•
•
Display the conveyor transfer speed
To display the conveyor transfer speed on
OPX-2A
, set the conveyor gear ratio by
using the formula below:
=
Conveyor speed
reduction ratio
1
Feed rate per motor revolution
Gear ratio of gearhead
Pulley diameter [m] × π
=
When the calculated conveyor speed reduction ratio is used, the conveyor transfer
speed is converted as follows.
=
Rotation speed of motor output shaft [r/min]
Conveyor speed reduction ratio
Conveyor transfer speed
[m/min]
Conveyor
transfer speed
Pulley
diameter
Example:
The pulley diameter is 0.1 m and gear ratio (speed reduction ratio) of the gear head is 20
䍦
63.7
Conveyor speed reduction ratio =
Gear ratio of gearhead
Pulley diameter [m] × π
=
20
0.1 [m] × π
From the conversion formula, the conveyor speed reduction ratio is calculated as 63.7 in this example. This means
that the "speed reduction ratio" parameter (ID: 2085) is 637, while the "speed reduction ratio digit setting" parameter
(ID: 2086) is 1.
When the speed reduction ratio is 63.7 and the motor rotation speed is 1300 r/min, the conveyor transfer speed is
converted as follows:
䍦
20.4
1300
63.7
Conveyor transfer speed [m/min] =
"20.4" is displayed on the
OPX-2A
.
Motor parameter
All parameters can be set in both the speed control mode and position control mode.
The parameters that can be used vary depending on the control mode.
ID Parameter name
Description
Setting range
Initial
value
Effective
*
1
Control mode
*
2
Speed
control
Position
control
290 Position loop gain Adjusts the motor response in reaction to
the position deviation.
1 to 100 Hz
7
A
○
*
3
○
291 Speed loop gain Adjusts the motor response in reaction to
the speed deviation.
1 to 1000 Hz
200
○
292
Speed loop
integral time
constant
Adjusts the deviation that cannot be
adjusted with the speed loop gain.
0 to 1000 ms
33
293 Speed filter
Adjusts the motor response.
0 to 200 ms
1
B
○
*
3
294 Moving average
time
Sets the time constant for the moving
average filter.
1 to 200 ms
1
2064 Speed filter
selection
Sets the filter function to adjust the motor
response.
0: Without speed filter
1: Speed filter
2: Moving average
0
C
*1•
Indicates the timing for the data to become effective.
(A: Effective immediately, B: Effective after stopping the operation, C: Effective after turning on the power again)
*2•
○
: Possible to use.
×
: Not possible to use.
*3•
Possible to use when the "servo lock at motor standstill" parameter (ID: 2069) is set to "1: Servo lock."