When using the product with the speed control mode
−26−
Downloading to the driver
In this operation, data in the specified data bank number are
downloaded to the driver.
Download
OPX-2A
data to the driver.
Driver
Data bank selection 0
Data bank
selection 3
Download successful
(blinking)
Top screen in
the download
Note
•
Some parameters will become effective after cycling the power. When these parameters were
changed by downloading, cycle the driver power.
•
Do not turn off the driver power while the download is still in progress (=while the display is
blinking). Doing so may damage the data.
If a download error occurs, a code indicating the nature of the error will blink on the display. Download will not be
performed and the display will return to the top screen of download.
Blinking display
Description
Action
The product series of the driver to which
data is downloaded is wrong.
•
Check the product series of the driver.
•
Check the data bank number on the
OPX-2A
.
An error occurred while data was being
downloaded.
Execute download again. If the same error
occurs, the data saved in the
OPX-2A
may be
damaged. Upload the applicable data to set the
OPX-2A
data again.
The specified data bank number does
not contain data.
Check the data bank number.
Uploading to the
OPX-2A
In this operation, data saved in the driver is uploaded to the
specified data bank number.
Upload driver data
to the
OPX-2A
.
Drive
Data bank selection 0
Data bank
selection 3
Upload is still in progress
(blinking)
Top screen in
the upload
Note
Do not turn off the driver power while the upload is still in progress (=while the display is blinking).
Doing so may damage the data.