![Orientalmotor BXII Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/orientalmotor/bxii-series/bxii-series_operating-manual_1651190019.webp)
When using the product with the speed control mode
−19−
Setting items
Item
Initial
value
Setting range
Description
Setting
unit
Operation speed
0
0 to 4000 r/min Sets the operation speed for the speed control operation.
Set as the rotation speed of the motor output shaft.
1
Torque limiting
250
0 to 250%
*
Sets when limiting the motor output torque.
Sets the torque limiting value based on the rated torque
being 100%.
1
Acceleration time
0.100 0.000 to 30.000 s
The acceleration time is set as the time needed for the
motor to reach the rated rotation speed (3000 r/min) from
the standstill state.
0.001
Deceleration time
The deceleration time is set as the time needed for the
motor to stop from the rated rotation speed (3000 r/min).
Data clear
–
–
Restores the operation data to the initial value.
–
*•
The motor may not start operating with the torque limiting value depending on variations in load torque, individual
differences in motors, gearheads or drivers, as well as operating environment.
Set the torque limiting value with providing a margin of 20% or more as a guide.
Initialization of all operation data
All of the operation data saved in the driver can be restored to the initial values. Execute "Initialize operation data" of