11
09.07/WE
ORGAPACK OR-V 41 P
1
4
7
9
11
10
Fig. 2
1b
4.1 OPERATING THE TOOL
Sealing
– Place the sealer OR-V 41 P on top of the seal.
– Actuate the lever, the seal is notched.
Do
not
put
your
fi ngers into the sealing area!
The sealer unit can be turned 90° (Fig. 1b) by
easy
modifi cations (see Chapter 5.2).
Fig. 1
4
OPERATING INSTRUCTIONS
5
PREVENTIVE AND CORRECTIVE MAINTENANCE
Fig. 3
5.1 REPLACING JAWS AND NOTCHER
Removal
– Disconnect sealer from air supply.
– Remove two lock washers (3/11), remove cylinder
screws (3/1) and covers (3/9).
– Remove counter sunk screw (3/2) and remove
bolt (3/8) with counter sunk screw.
– With help of a big screwdriver withdraw and block
slider (3/10). Remove both side plates (3/3).
– Remove notcher (3/4) and jaws (3/5) frombolts (3/6)
and (3/7), clean parts and if necessary replace.
Installation
– Install the parts in reverse order.
Check of seal
To obtain the maximum seal effi ciency, the notches
have to be cut properly into the seal. If these notches
are not correctly cut, replace jaws and notcher (see
Chapter 5.1).