8 Maintenance
Operating instructions RA 41 Plus (H)
32
(07.08)
MT_RA 41 Plus (H)_BA_04_790046773_04.doc
orbitalum tools
gmbh
8.1
Checking the level of the gear oil
X
Using the grip, turn the motor counter-clockwise from its home position by
approx. 120° until the marking (3) on the rotary element is in line with the
notch on the housing (approx. 8 o'clock position).
The oil level should be visible in the middle of the oil level viewglass (1).
8.2
Topping up gear oil
X
Check the oil level through the oil-level viewglass as described above and
top up with oil if necessary.
1. Undo the oil filler plug (2).
2. Fill with special Orbitalum Tools gear oil.
3. Keeping the motor in this position, check the oil level. Continue to top up
with oil until the oil level is visible in the middle of the oil level viewglass.
Topping up: