1. Press the "
Calibrate motor
" button.
The rotor moves to the home position and then carries out one complete revolution at a speed which is realistic for the
welding process. The time is measured during the revolution. The (actual) speed which can be calculated is compared to
the default value. The deviation is displayed in the speed in percent.
Properly calibrated heads generally mean deviations under 1%.
A message appears: "
Save new calibration data??
"
2. If the deviation is less than 1%: Confirm message with "
No
".
3. If the deviation is greater: Confirm the message with "
Yes
" and save the value.
The machine is aware of the fault of the current connected weld head and compensates for it in the process.
Fig. 32:
Motor calibration
WARNING
When a display appears (see Fig. 32), the weld head can be calibrated!
1. Ensure that the head can rotate freely and that there is no danger of injury.
2. Message: Confirm "
Weld head ready for calibration?
" with "
Yes
".
The weld head starts running.
The calibration can be aborted at any time by pressing the rotary knob.
Motor calibration is only possible with heads that have a limit switch.