Service and troubleshooting
ORBIMAT 180 SW
| Operating instructions
64
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
(17.09.18) OW_ORBIMAT_180SW_BA_850060202_00_EN
9. SERVICE AND TROUBLESHOOTING
9.1
Performing service work
X
In the main menu select "
System settings
" > "
Service
".
The following display appears:
Fig. 31:
Service menu
9.1.1
Pumping out coolant
Use when changing the coolant and emptying the tank in case of longer machine standstill
1. Connect the drain hose on the flow connection (blue).
2. Lead drain hose into a suitable container to catch the coolant water (approx. 2.2 liters).
3. Press the "
Coolant pump on
" button.
A message appears. The coolant is pumped out of the flow connection of the machine (blue) without the coolant sensor
in the return line being able to interrupt the process. To protect the pump against dry running, this process is limited in
time to approx. 30 seconds.
4. Select "
Cancel
" when the coolant is fully pumped out to avoid unnecessary dry running of the pump.
If the tank is not pumped empty:
X
Start the process again.
For further information please refer to the "Commissioning" section (see chap. 7.5, p. 25).
9.1.2
Performing motor calibration
Use to check and correct the motor speed.
If several weld heads of the same type are used, a motor calibration should be carried out repeatedly before use.
If different weld head models are used, this is not required, as the machine saves a separate deviation for each head
model.
Continuously large and constantly different speed deviations are an indicator of a defect in the power source or weld
head that cannot be compensated via motor calibration.