9 What to do if …?
Operating instructions GF 4 (AVM / MVM)
46
(01.08)
MT_GF 4_BA_04_790142762_01.doc
orbitalum tools
gmbh
Error message/fault
Possible cause
Remedy
Display F5:
Excess temperature.
The temperature of the control
system is too high.
X
Self-regulating after cooling down.
Display F6:
Internal control error.
Wrong basic setting.
X
Contact the service department.
No display:
The AVM does not start.
The cutter motor is not running or is
not running long enough.
X
The cutter motor must be running
for at least 5 seconds before the
AVM can be started.
Blocking by chips.
X
Remove
the
chips.
Pipe diameter not correctly set.
X
Correct the adjustment.
The feed stops at the cut-in area.
Saw blade worn out.
X
Insert new saw blade.
Light barrier or reflector defective.
X
Replace the defective parts
(contact the service department, if
necessary).
The feed does not stop at the stop
position.
Display: No decimal point at the stop
position.
Light barrier or reflector dirty.
X
Clean the dirty parts.
After having remedied the cause of malfunction, the AVM has to be re-
connected to the mains supply. After having switched off the cutter motor
(to position “0”), it may be restarted.
9.3 Servicing/after-sales
service
For ordering spare parts, see the separate spare parts list. For trouble-
shooting, please contact your competent branch office directly.
Please state the following details:
•
Machine
type:
GF 4, GF 4 AVM
or
GF 4 MVM
•
Machine
number:
(see Identification plate)
Содержание GF 4 AVM
Страница 51: ......