Operating instructions GF 4 (AVM / MVM)
2 Design of the product
orbitalum tools
gmbh
(01.08)
MT_GF 4_BA_04_790142762_01.doc
9
2.2
Automatic Feed Module AVM
1
Display
5
Buttons for presetting the feed force level
2 START
button
6 Light
barrier
3 STOP
button
7 Reflector
4 EMERGENCY
OFF
button
8 Protective
web
2.2.1
Description of the AVM buttons
If the control system is connected to the mains, the number of the current
software version will first appear on the display for approx. 1 second. If the
module is ready for operation, the currently preset feed force level will be
displayed. In case of a malfunction, this display will flash at 1-second intervals
showing
F
and a figure from
1
to
6
. For error messages/trouble-shooting,
see chapter 9.2, p. 44.
By actuating these buttons, it is possible to preset the desired feed force in
9 levels. If the device is ready for operation, these buttons may be pressed at
any time to set the feed force level or to vary it during processing. If one of the
buttons remains pressed by the user, the display will run to the respective
direction selected by the user.
The machining process is initiated by actuating this button. After start-up, this
button serves no further function. It remains also without function during a fault
or while the software version is being displayed.
During the machining process
, a stop cycle is initiated by actuating this
button, and a new start is waited for.
Before and after the machining process
, the feed will run backwards as long
as the button is pressed, regardless whether the cutter motor is running or not.
During a fault
, the button remains without function. For error messages/
trouble-shooting, see chapter 9.2, p. 44.
Display
PRESET buttons
/
START button
STOP button
1
2
3
4
5
8
7
6
Содержание GF 4 AVM