5518-FM DIGITAL
INSTALLATION
2-41
1.
Navigate to
Setup
>
Next
>
N
ETWORK
&
R
EMOTE
>
R
EMOTE
I
NTERFACE
.
2.
Program one or more remote control interfaces.
A)
Navigate to the desired Remote Interface button (1 through 8) by repeatedly
pressing the
Next
button.
B)
Hold down the button while turning the knob to select the desired function
for the interface.
Use either button below the appropriate graphics; both work the same.
A momentary pulse of voltage will switch most functions except as noted.
Preset Name
: switches the named preset on the air. The control interface
can recall any factory or user preset.
Input
:
Analog
: selects the analog inputs.
Input
:
Digital
: selects the digital input and but does not apply deempha-
sis to it.
Input
:
J.17
: selects the digital input and applies J.17 deemphasis
to it.
Independently activate and defeat the
diversity
delay
applied to the
analog, digital, and composite outputs.
Bypass
: switches the Bypass Test Mode on the air.
Tone
: switches the Tone Test Mode preset on the air.
Exit Test
: If a test preset is presently on the air, EXIT
TEST reverts to the previ-
ous processing preset.
Stereo
: Determines the operating mode of the audio processing (
S
TEREO
,
M
ONO
-
F
ROM
-
LEFT
,
M
ONO
-F
ROM
-R
IGHT
,
M
ONO
-F
ROM
-S
UM
,
or
SSB
.)
Mono from Left, Mono from Right, or Mono from Sum
: switches the 5518’s
stereo encoder off, using the Left, Right, or Sum (L+R) respectively as the pro-
gram source. This also determines the feed to the entire processing chain so that
facilities that do not use the 5518’s stereo encoder can change stereo/mono
mode and select the source when in mono mode.
SSB
:
switches the 5518 to its experimental compatible SSB/VSB mode. See
SSB
Stereo Encoder Operation
on page 3-6 for more information.
Mod Reduction 1, or Mod Reduction 2
: reduces the program modulation by
the percentage programmed in S
ETUP
>
N
EXT
>
M
ODULATION
R
EDUCTION
(see step 17
on page 2-15). When voltage is removed, these functions are deactivated.
Reset Clock To Hour
: resets the internal clock to the nearest hour. For exam-
ple, 3:03:10 would be reset to 3:00:00, while 3:53:40 would be reset to 4:00:00.
Содержание OPTIMOD-FM 5518
Страница 1: ...Operating Manual OPTIMOD FM 5518 FM Stereo Encoder Version 1 2 Software...
Страница 7: ...Operating Manual OPTIMOD FM 5518 FM Stereo Encoder Version 1 2 Software...
Страница 20: ......
Страница 191: ...5518 FM DIGITAL TECHNICAL DATA 6 25...
Страница 192: ......
Страница 194: ...6 28 TECHNICAL DATA ORBAN MODEL 5518 CONTROL BOARD PARTS LOCATOR...
Страница 200: ...6 34 TECHNICAL DATA ORBAN MODEL 5518 5500 I O BOARD Parts Locator Drawing 32370 000 02 1 sheet 1 of 1...
Страница 205: ...5518 FM DIGITAL TECHNICAL DATA 6 39 5500 I O BOARD Composite SCA Daughter Board 62310 000 02 1 sheet 4b...
Страница 214: ...6 48 TECHNICAL DATA ORBAN MODEL 5518 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM...
Страница 217: ...5518 FM DIGITAL TECHNICAL DATA 6 51...