25
EN
1
When the unit is turned on for the first time, the melody sounds and
the display shows the ambient temperature. The range of displayed
temperatures is from 16 to 30 °C. If the temperature is above 35 °C, H is
displayed if the temperature is below 10 °C, L is displayed and the unit
enters standby mode.
2
POWER button to turn the unit on / off. When the POWER button is
pressed, the unit is activated, after power-up, the Power light turns on green
(if available), the melody sounds and the unit enters cooling mode. The
display will show the ambient temperature. Fan speed is set to High. The
power indicator lights green and the High light also lights up.
Press the POWER button again to turn off the unit, all operations are
ended, the melody is switched on, and the unit switches to standby mode.
When the unit is restarted, the state used before turning it off is activated.
3
Mode button (MODE):
a)
Models with cooling only:
Press the MODE button to switch the unit mode between Cool mode, Fan
mode, Dry mode. Sleep mode can only be activated by the remote control
and in Cool mode only. The Cool, Fan, Dry indicator lights up according to
the selected mode.
b)
When the ambient temperature is ≥ 16 °C in dry mode (Dry), the
compressor starts. Then the unit works as follows:
If the ambient temperature is ≤15 °C, the compressor switches off.
If the ambient temperature rises to ≥17 °C, the compressor will start again.
The compressor triggers with a delay of 3 minutes to protect it, and then
shuts off for another 3 minutes after switching off. The fan is forced to switch
to low speed.
c)
In Sleep mode, the unit performs the cooling function. To select Sleep
mode, activate the air conditioner to Cool mode. Then, in the cooling mode,
press the Sleep button on the remote control. The Sleep indicator lights up,
the air conditioning switches to Sleep mode and the fan switches to low
speed.
After two hours of operation, the set temperature is automatically increased
0 °C. After another two hours of operation, the set temperature is
automatically increased by 1 °C. Subsequently, the set temperature will not
change.