Identify and Remove a Faulty DIMM
Servicing CRUs That Require Server Power-Off
109
you press the Fault Remind button, it is likely that the capacitor powering the fault remind
circuit has lost its charge. This can happen if the Fault Remind button is pressed for several
minutes with fault LEDs lit or if power has been removed from the server for more than 15
minutes.
The following figure shows the location of the Fault Remind button.
FIGURE 29
Fault Remind Button Location
Identify and Remove a Faulty DIMM
1.
Prepare the server for service.
a.
Power off the server, and disconnect the power cords from the server power
supplies.