Resolved Issues
■
Sun Fire X4170 M2 Server
■
Sun Fire X4270 M2 Server
■
Releases 1.0 through 1.10.1
■
ILOM 3.2.8.21
Workaround:
Do not create multiple configuration changes without verifying the effect of each configuration
change. To prevent misconfigured users and missed traps, insert sleep statements in the script.
For example:
# change engineID
set /SP/services/snmp engineid=NEWENGINEID
# sleep 10 seconds to give snmp enough time to make the change
sleep 10
# verify engineID
show /SP/services/snmp engineid
# verify SNMPv3 users have been deleted
show /SP/services/snmp/users
# create snmpv3 user
create /SP/services/snmp/users newuser authenticationpassword=...
# sleep 10 seconds to give snmp enough time to make the change
sleep 10
# verify user
show /SP/services/snmp/users newuser
# do a snmpget with that user to verify it
# configure alert
set /SP/alertmgmt/rules/1 type=snmptrap ...
# sleep 10 seconds to give snmp enough time to make the change
sleep 10
# verify alert
show /SP/alertmgmt/rules/1
set /SP/alertmgmt/rules/1 testrule=true
Oracle ILOM Remote Console might hang on Windows client
when redirecting a CD-ROM image or floppy image
Bug ID 15542570
Oracle ILOM Remote Console might hang on Windows client when redirecting a CD-ROM
image or floppy image.
Issue:
46