Known Issues
■
Sun Fire X4170 M2 Server
■
Sun Fire X4270 M2 Server
Workaround:
Do not use the Oracle ILOM CLI or GUI to reset the server during POST until after you see
output on the video display.
If the faults do occur:
1. Clear the faults using the Oracle ILOM command-line interface (CLI) command:
set /SYS/MB/
Px
/
Dy
/ clear_fault_action=true
Where
Px
/
Dy
identifies the DIMM the fault was reported against.
2. Power cycle the system.
Warning messages appear when booting Oracle Solaris
Bug ID 17658302, 18257238
Warning messages appear when booting a server with Oracle Solaris 10 that has a Sun
InfiniBand Dual Port 4x QDR PCIe Low Profile Host Channel Adapter M2 card. For example:
NOTICE: unsupported 64-bit prefetch memory on pci-pci bridge (128/3/0)
NOTICE: hermon0: error during attach: UAR BAR mapping
NOTICE: hermon0: driver failed to attach: UAR BAR mapping
WARNING: kstat_create('unix', 0, 'hermon_rsrc_cache00000000'): namespace
collision
Affected Hardware:
■
Sun Fire X4170 M2 Server
■
Sun Fire X4270 M2 Server
Workaround:
Use the BIOS Setup Utility to disable PCI MMIO 64 Bits Support.
Solaris 10 U11 Installation Might Fail with InfiniBand Option
Card Installed
Bug ID 19236137
Sun Fire X4170 M2 and X4270 M2 Servers Product Notes
29