Verify Operation of Slide Rails and CMA
Verify Operation of Slide Rails and CMA
Note -
Two people are recommended for this procedure: one to move the server in and out of
the rack, and one to observe the cables and CMA.
1.
Slowly pull the server out of the rack until the slide rails reach their stops.
2.
Inspect the attached cables for any binding or kinks.
3.
Verify that the CMA extends fully from the slide rails.
4.
Push the server back into the rack.
When the server is fully extended, you must release two sets of slide rail stops to return the
server to the rack.
a.
The first set of stops are levers, located on the inside of each slide
rail, just behind the rear panel of the server. Push in both green levers
simultaneously and slide the server toward the rack.
The server will slide in approximately 18 inches (46 cm) and stop.
Verify that the cables and the CMA retract without binding before you continue.
b.
The second set of stops are the slide rail release buttons, located near the
front of each mounting bracket. Simultaneously push both of the green slide
rail release buttons, and push the server completely into the rack until both
slide rail locks engage.
5.
Adjust the cable straps and CMA, as required.
Related Information
■
■
“Secure Cables to the CMA” on page 52
Installing the Server
39
Содержание SPARC T7-2
Страница 1: ...SPARC T7 2 Server Installation Guide Part No E54986 03 March 2016 ...
Страница 2: ......
Страница 8: ...8 SPARC T7 2 Server Installation Guide March 2016 ...
Страница 14: ...14 SPARC T7 2 Server Installation Guide March 2016 ...
Страница 40: ...40 SPARC T7 2 Server Installation Guide March 2016 ...
Страница 74: ...74 SPARC T7 2 Server Installation Guide March 2016 ...