background image

No Wiring or Trenching 

Required

Made With Pride In the USA.                                                                                                                                               

A manufacturer’s Limited Lifetime Warranty covers this product.

Oracle

 limited LIFETIME WARRANTY 

 
 

International  Electronics  Inc.  (IEI)  warrants  this  product  to  be  free  of  defects  in  materials  and 
workmanship, for its usable lifetime. For a period of ONE YEAR following purchase, IEI will repair or 
replace the product free of charge, including parts, labor, return shipping to you, and handling.  
 
After  the  initial  one  year  of  operation,  the  limited  lifetime  warranty  will  cover  parts,  labor,  and  return 
shipping to you, with a minimal handling charge specific to the product, as listed below: 

 

Gate Access Panel (with Keypad): 

$55.00 

Oracle Flush Mount Intercom: 

$20.00 

Gate Controller Unit: 

$30.00  

Telephone Interface unit:  

$40.00 

Key-fob Remote: 

$10.00 

Repeater System: 

 

$40.00 

Outdoor Intercom (no keypad): 

$35.00 

Oracle Portable Intercom: 

$20.00 

 

 

INSTALLER:

  If you have installation questions, please contact your Distributor.   

CONSUMER BEFORE INSTALL:

  If you have questions, please contact your Installer.   

CONSUMER AFTER INSTALL:

  If you have operation questions or are in need of warranty 

service,  please  contact  our  Product  Support  department  by  email  at 

[email protected] 

or call 

360-254-1564  Tuesday-Friday  7-5  Pacific  Time.  If  the  issue  is  not  resolvable,  a  manufacturer’s 
warranty  repair  order  may  be  issued.  To  have  the  product(s)  sent  for  warranty  service.    A  Return 
Authorization  number  will  be  issued  for  warranty  service,  which  must  be  put  on  the  outside  of  the 
package,  to  be  received  and  handled  properly.    Packages  for  warranty  service  may  be  sent  to  the 
following address. Packages with no RA# may not be accepted. 
 

IEI 

5913C NE 127th AVE,  Suite 800 

Vancouver, WA  98682  

 

Please include a note describing the problem that you are having and 

a copy of your original sales 

receipt

 (within the first year). If the warranty service  is outside the first year, please include a check 

made  out to IEI, based on the list of handling fees, shown above. Please note that you may need to 
send  multiple  units  for  warranty  service,  testing,  and  upgrading,  though  only  the  applicable  fee  for 
handling the failed unit(s) will be charged.  
 
Please  allow  2-4  weeks  for  service  and  return  shipping.  If  an  EXPEDITED  repair/replacement  is 
requested,  a  100%  surcharge  applies.  In  this  case,  please  write  EXPEDITED  after the RA number. 
IEI will attempt to return expedited repair orders within one week, except during holidays. 
 
All  repairs  or  replacements  are  at  the discretion of the Manufacturer.   This warranty excludes items 
that  have  been  abused,  altered,  incorrectly  installed,  or  repaired  by  an  unauthorized  person. 
Changes  or  modifications  not  expressly  approved  by  the  Manufacturer  could  void  the  user’s 
authority  to  operate  the  equipment.  The  manufacturer  is  not  responsible  for  any  radio  or  TV 
interference caused by unauthorized modifications to this equipment.  Such modifications could void 
the  user’s  authority  to  operate  the  equipment.  This  warranty  is  limited  to  the  product  only.  No 
consequential damages are covered.

 

Oracle

(TM)

 

Wireless 

Keypad 

 

Thank  you  for  purchasing  the 
Oracle  Wireless  Keypad.  This 
product has been designed and 
manufactured  in  the  USA, 
utilizing  the  highest  quality 
standards available. 

• 

Controls up to four Gate Openers or other accessories 

• 

Multiple Control Modes 

• 

Proximity Detector with Backlit key-pad after dark 

 

• 

Echo Confirmation Feedback

 

• 

Up to 2 years on 4xAA batteries

 

• 

Multiple Power Saving Modes 

• 

Temporary one-time use/24 hour PIN numbers  

• 

Use Several Keypads together in Multi-Keypad Mode 

• 

Use 

Alternate 

Channel 

Groups 

to 

overcome 

interference 

• 

Oracle Wireless Keypad (OWK) has 2 models: 
OWK5 – 5 Pin Codes 
OWK250 – 250 Pin Codes 

 

This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation. 

 

International Electronics, Inc. 

FCC ID:  JLFKPD1 

IC: 

Country Of Origin:  USA

 

Model OWK

9/6/2007

Patents Pending

Содержание OWK5

Страница 1: ...to IEI based on the list of handling fees shown above Please note that you may need to send multiple units for warranty service testing and upgrading though only the applicable fee for handling the failed unit s will be charged Please allow 2 4 weeks for service and return shipping If an EXPEDITED repair replacement is requested a 100 surcharge applies In this case please write EXPEDITED after the...

Страница 2: ...the Gate Controller If the Gate Controller is 2 3 or 4 make sure that the corresponding ID is set with dipswitches 1 2 in the Gate Controller See Basic Gate Control Unit Installation I need the Manufacturer s Reset Code to reset my Wireless Keypad Unit The Wireless Keypad Unit s serial number is printed on the inside of the Wireless Keypad Unit s mounting plate Call our Product Support staff at 88...

Страница 3: ...newest wireless protocols this keypad product line is able to meet and exceed the most stringent security and environmental requirements Ultra long Range Low Power Usage and its Two Way design which provides Confirmation Feedback of Receiver Action make this system the most robust available 1 2 3 4 Sample Configuration 3 Open Close Gate and Verify Gate Status Use this configuration when you wish t...

Страница 4: ... or a magnetic loop Enable the Auto close feature on your Automatic Gate Opener Connect the Reporter Gate Controller as shown in the Basic Gate Controller Installation diagram Please refer to your product specific manual for wiring information On the Reporter Intercom disable gate status checking as described above Sample Configuration 2 Wiring to separate OPEN and CLOSE terminals Use this configu...

Страница 5: ...an proceed to the next step For additional GCU s repeat the process until all GCU s have been successfully activated Note You can now assemble the GCU by snapping the box shell back onto the unit 1 4 Selecting Gate Controller ON Time For most connections to an Automatic Gate Opener the default setting of second is best However for connection to yard lights cameras etc you may wish to adjust how lo...

Страница 6: ... From left to right Gate Controller Terminals are Optional power input 9Vto 24VDC Make sure that your gate s DC power supply Ground is wired to terminal 2 Ground or Common terminal Limit switch input A Wire such that when the limit switch is closed terminal 4 is shorted to terminal 3 Limit switch input B Wire such that when the limit switch is closed terminal 4 is shorted to terminal 3 Secondary R...

Страница 7: ...l functions enabled Enabling Power save Mode can extend the battery life up to two years Enable OWK Learn Mode PIN 05 Add User Level PIN numbers PIN 9 PIN Add User Level PIN numbers w GCU restrict PIN 9 PIN 1 4 Add a Temporary PIN number PIN 51 PIN Add a Temporary PIN number w GCU restrict PIN 51 PIN 1 4 Removing PIN numbers PIN 7 PIN Change the Master PIN number PIN 09 PIN OWK Brightness Control ...

Страница 8: ...xit Party Mode cycle the gate by entering a PIN number or by pressing the button on a Remote or Intercom If you are going to be gone for an extended length of time the unit can be put into a Deep Sleep mode to conserve power and will only respond to the Master PIN number being entered on the Wireless Keypad Unit To enter Vacation Mode Enter the Master PIN Number for example Followed by To exit Vac...