How to Replace a ZS4-4 HDD or SSD
Note -
If you have more than one failed drive, replace only one drive at a time. Removing more
than one drive in quick succession will cause a hardware/pool fault. Also, do not perform a pool
configuration operation while a disk firmware upgrade is occurring. To check if an upgrade is
in progress, navigate to Maintenance > System in the BUI, or
maintenance system updates
in
the CLI.
1.
Identify the failed HDD or SSD.
If you are not physically at the system, go to the Maintenance > Hardware section of the BUI,
click the right-arrow icon for the controller, and note the ID of the faulted drive, which has an
amber icon. To highlight the location of the drive in the controller picture, click on the drive
ID. To view details about the faulted drive, click its information icon and then click Active
Problems.
If you are physically at the system, the amber Service action required indicator on the HDD
or SSD should be lit. Additionally, you can click the locator icon
in the BUI to flash the
locator indicator on the faulted drive.
2.
Verify that the Ready to Remove indicator is lit on the faulted drive.
3.
On the drive you want to remove, push the drive release button (1) to open the
latch.
4.
Grasp the latch (2) and pull the drive out of the drive slot (3).
5.
After at least 30 seconds, go to the Hardware > Maintenance screen, and click
the right-arrow icon on the system controller to verify that the software has
detected that the drive is not present.
Servicing the Hardware
59