How to Replace a Faulty Disk Shelf Drive
Use the following procedure to replace a faulty drive. The disk shelf drives are hot-swappable
and may be replaced without removing power from the disk shelf. The replacement drive must
be of the same capacity and type as the drive to be replaced. To avoid possible data loss when
removing non-faulted drives, label each drive with the number of the slot from which it was
removed and reinstall each drive into the same slot.
Note -
Do not perform a pool configuration operation while a disk firmware upgrade is
occurring. To check if an upgrade is in progress, navigate to Maintenance > System in the BUI,
or
maintenance system updates
in the CLI.
1.
Faulted drives are indicated by an amber LED. Go to the Maintenance >
Hardware section of the BUI, click the right-arrow icon at the beginning of the
appropriate disk shelf row, and click the information icon for the appropriate
drive to view details, or click the locator icon
to turn on the locator LED. To
add, not replace, a new cache device into an appropriate and empty drive slot,
“How to Add a Disk Shelf Cache Device” on page 264
.
2.
Locate the failed disk drive with an amber LED at the front of the chassis.
3.
Press the release button or latch to release the drive lever.
4.
Pull the drive lever fully open to unlock and partially eject the drive from the
chassis.
250
Oracle ZFS Storage Appliance Customer Service Manual • February 2016
Содержание DE2-24
Страница 2: ......
Страница 8: ...8 Oracle ZFS Storage Appliance Customer Service Manual February 2016 ...
Страница 10: ...10 Oracle ZFS Storage Appliance Customer Service Manual February 2016 ...
Страница 71: ...How to Replace a ZS4 4 PCIe Card 8 Ensure the PCIe card retaining bar is open Servicing the Hardware 71 ...