![Oracle DE2-24 Скачать руководство пользователя страница 176](http://html1.mh-extra.com/html/oracle/de2-24/de2-24_customer-service-manual_1646220176.webp)
Servicing the 7x20 Controller
Figure Legend
Figure Legend
1
Power supplies
4
Network management port
2
SC summary status LEDs
5
Ethernet ports
3
Serial management port
6
PCIe slots
7320 Electrical Specifications
The following list shows the electrical specifications for the 7320.
Note -
The power dissipation numbers listed are the maximum rated power numbers for the
power supply. The numbers are not a rating of the actual power consumption of the appliance.
Connectors
■
Two C13 connectors which work on 110-220v outlets
Input
■
Nominal frequencies: 50/60Hz
■
Nominal voltage range: 100-120/200-240 VAC
■
Maximum current AC RMS: 9.0 amps Max
■
AC operating range: 90-264 VAC
Output
■
3.3 VDC STBY: 3.6A
■
+12 VDC: 62.3A
Power Dissipation
■
Max power consumption: 873 W
■
Max heat output: 2977 BTU/hr
■
Volt-Ampere rating: 891 VA @ 240 VAC, 0.98P.F.
7320 Internal Boards
The 7320 storage controller chassis has the following boards installed.
Note -
Field-replaceable units (FRUs) should only be replaced by trained Oracle service
technicians.
176
Oracle ZFS Storage Appliance Customer Service Manual • February 2016
Содержание DE2-24
Страница 2: ......
Страница 8: ...8 Oracle ZFS Storage Appliance Customer Service Manual February 2016 ...
Страница 10: ...10 Oracle ZFS Storage Appliance Customer Service Manual February 2016 ...
Страница 71: ...How to Replace a ZS4 4 PCIe Card 8 Ensure the PCIe card retaining bar is open Servicing the Hardware 71 ...