SANE with Optocore
6 / 10
rev. 2.21.024
EXAMPLE 2: Five TP devices, one with two AES/EBU ports enabled
An Optocore X6R-FX is connected to five X6R-TP devices by SANE. The third TP device in the daisy chain is
configured with both AES/EBU ports enabled and connected to generic 3
rd
party converters as shown below.
This system would be configured as shown below:
1) In ID8 - Software Local Settings - Sane setup:
a. TP – ID 2: X6R-8MicIn/8LineIn
b. TP – ID 3: X6R-8DualMic
c. TP – ID 4: X6R-16MicIn
d. TP – ID 5: Generic, 8/8 Standard
e. TP – ID 6: Generic, 16 Out
f. TP – ID 7: X6R-16LineOut
g. TP – ID 8: X6R-16LineOut
2) In the third X6R-TP – Local Settings:
a. ID: 4
b. Parent ID: 8
c. AES port A: Generic, 8/8 Standard
d. AES port B: Generic, 16 Out
3) In the first, second, fourth and fifth X6R-TP– Local Settings
a. ID: 2, 3, 7, 8 (depending on the position of the
device in the daisy-chain)
b. Parent ID: 16
c. AES port A and B: Disabled
TP-ID 4
TP-ID 2
FX unit - Local Settings – Sane Setup
TP devices - Local Settings
Содержание SANE TP Series
Страница 2: ...Page intentionally left blank ...