This  document  is  intended  to  be  a  brief  introduction  on  how  to  use  Optocore  SANE  TP  devices  to  expand  the 
number  of  inputs  and  outputs  on  Optocore  FX  devices.    The  document  assumes  that  an  Optocore  system  has 
been configured according to the Optocore Quick Start guide and/or the Optocore Software Manual. 

 

SANE expander setup 

Optocore SANE TP network devices can be used to expand the number of inputs and outputs on Optocore FX 
devices. 

Configuration  of  SANE  TP  expanders  is  set  in  the  Software  Local  Settings  of  the  Optocore  FX  device  and  the 
Local Settings of the SANE TP device.  

1)  Open the system Configuration window (Drop down menu: “Set” -> “Configuration”) 

2)  Enter the Software Local Settings of the Optocore FX device (Local Settings Column -> “Setup” button) 

3)  Set  the  TP  device  type  for  TP-ID  2-8  (TP-IDs  5-8  when 

configuring DD32R-FX) as required. 

By default the AES/EBU ports on TP devices are disabled. 

a)  To enable AES/EBU Port A on a TP device 

  Configure  the  first  TP-ID  that  follows  the  TP  device 

requiring an active AES/EBU port as “Generic” 

 Select the required “I/O Configuration” for AES/EBU port A 

b)  To enable AES/EBU Port B on a TP device 

  Configure  the  TP-ID  that  follows  AES/EBU  port  A  as 

“Generic” 

 Select the required “I/O Configuration” for AES/EBU port B 

 

4)  Click “OK” and in the “Configuration” window click “OK & Write” 

5)  Connect to the Optocore FX device with a USB, Ethernet or RS232 cable and “Write” the Local Settings 

to the device 

6)  Connect to the SANE TP device with a USB, Ethernet or RS232 cable. 

7)  Enter the Local Settings of the SANE TP device (Drop down menu: “Set” -> “Local Settings”) 

8)  Set  the  “ID”  to  match  the  Sane  port  “TP-ID”  configured  in 

the Optocore FX device’s Software Local Settings  

9)  Set the “Parent ID” to the ID of the Optocore FX device that 

is connected to the SANE TP device 

10)  If  utilising  the  AES/EBU  port(s)  of  the  SANE  TP  device, 

configure  the  AES  port  “I/O  Configuration”  to  match  the 
setup in the Optocore FX device. 

11)  Write the Local Settings to the SANE TP device. 

12)  Connect  the  SANE  link  from  the  Optocore  FX  device’s 

SANE 1 port to SANE TP device’s SANE 2. 

13)  Connect the SANE link from SANE 1 to SANE 2 trough all devices.  

Do not connect the SANE link back to the Optocore FX device.   

Example:

 

The screenshot shows X6R-TP-16MI SANE device with TP-ID 2 configured to have both 
AES/EBU port A and B enabled for a total of 8 AES inputs and 24 AES outputs.  
The next SANE TP device is assigned to TP-ID 5. 

 

 

 

 

 

FX unit - Local Settings – Sane Setup 

TP ID 2 - Local Settings 

Содержание SANE TP Series

Страница 1: ...uick Start Guide Rev 2 21 024 SANE with Optocore Quick Start Guide Using SANE TP devices as expanders for Optocore FX devices Rev 2 21 024 Copyright 2020 All rights reserved OPTOCORE GmbH Alte Allee 28 81245 Munich Germany ...

Страница 2: ...Page intentionally left blank ...

Страница 3: ... Port B on a TP device Configure the TP ID that follows AES EBU port A as Generic Select the required I O Configuration for AES EBU port B 4 Click OK and in the Configuration window click OK Write 5 Connect to the Optocore FX device with a USB Ethernet or RS232 cable and Write the Local Settings to the device 6 Connect to the SANE TP device with a USB Ethernet or RS232 cable 7 Enter the Local Sett...

Страница 4: ...elect Set Configuration In the Local Settings column click Setup for the device to be configured Configure as needed Click OK In the Configuration window click OK Write The computer must be connected to the Optocore FX with USB Ethernet or RS232 Locate the device from the device list and click Write To access and configure Local Settings on a SANE TP device The computer must be connected to the SA...

Страница 5: ... configured as shown below 1 In ID16 Software Local Settings Sane setup a TP ID 2 X6R 16MicIn b TP ID 3 X6R 8DualMic c TP ID 4 X6R 8MicIn 8LineOut d TP ID 5 X6R 8MicIn 8LineOut e TP ID 6 X6R 16LineOut f TP ID 7 X6R 16LineOut g TP ID 8 X6R 16LineOut 2 For each X6R TP Local Settings a ID 2 8 depending on the position of the device in the daisy chain b Parent ID 16 c AES port A and B Disabled The scr...

Страница 6: ...Local Settings Sane setup a TP ID 2 X6R 8MicIn 8LineIn b TP ID 3 X6R 8DualMic c TP ID 4 X6R 16MicIn d TP ID 5 Generic 8 8 Standard e TP ID 6 Generic 16 Out f TP ID 7 X6R 16LineOut g TP ID 8 X6R 16LineOut 2 In the third X6R TP Local Settings a ID 4 b Parent ID 8 c AES port A Generic 8 8 Standard d AES port B Generic 16 Out 3 In the first second fourth and fifth X6R TP Local Settings a ID 2 3 7 8 de...

Страница 7: ...igured as shown below 1 In ID22 Software Local Settings Sane setup a TP ID 2 X6R 16MicIn b TP ID 3 Generic 16 Out c TP ID 4 X6R 8MicIn 8LineOut d TP ID 5 Generic 16 In 2 In X6R TP 16MI Local Settings a ID 2 b Parent ID 22 c AES port A Generic 16 Out d AES port B Disabled 3 In X6R TP 8MI 8LO Local Settings a ID 4 b Parent ID 22 c AES port A Generic 16 In d AES port B Disabled FX unit Local Settings...

Страница 8: ... count for MADI Cat 2 should match number of cards x 16 E g for 2 cards 32 In and 32 Out should be configured This system would be configured as shown below 1 In ID4 Software Local Settings Sane setup a TP ID 2 X6R 16MicIn b TP ID 4 X6R 8MicIn 8LineOut c MADI Cat 2 IN AES10 2003 48 ch d MADI Cat 2 OUT AES10 2003 48 ch 2 In X6R TP 16MI Local Settings a ID 2 b Parent ID 4 c AES port A Disabled d AES...

Страница 9: ...ch number of cards x 16 E g for 2 cards 32 In and 32 Out should be configured sum for TP ID5 ID8 is 32 32 channels This system would be configured as shown below 4 In ID2 Software Local Settings Sane setup e TP ID 2 X6R 16MicIn f TP ID 3 X6R 16LineOut g TP ID 4 Generic 16 In h TP ID 5 Generic 8 8 Standard i TP ID 6 Generic 8 8 Standard j TP ID 7 Generic 16 In k TP ID 8 Generic 16 Out 5 In X6R TP 1...

Страница 10: ... with Optocore 10 10 rev 2 21 024 Contact Information Mailing Address OPTOCORE GmbH Alte Allee 28 D 81245 Munich Germany Telephone 49 0 89 8999640 Facsimile 49 0 89 89996455 Internet www optocore com Email ...

Отзывы: