Camera Functionalities
7. Self-test process
7.1 Variable speed
Control Mode
Horizontal direction
Vertical Direction
Regulative
Speed
0.1 to 280º/s, depend on joy
stick‟s position
0.1to 180º/s, depend on joy
stick‟s position
Preset Speed 0.1 to 280 º/s optional
0.1to 180 º/s optional
7.2 AUTO FLIP
When the camera turn down to perpendicular position, the camera will auto-rotate 180 º. If
the joy stick continue down, the camera will continue to uplift. Once you release joy stick after
the camera flip, the joy stick will recover to normal working. This function could be used to
track when someone pass the underneath of camera, it could also adopt auto flip function.
7.3 SCAN SPEED
The scan speed can be adjusted from 1~280º/s through program the speed dome camera
menu
7.4 PRESET FUNCTIONS
Preset function is setting and call preset position
Preset function is the speed dome camera take numeral(1-128) as position parameter ssuch as
level angle, perpendicular angle and camera lens focus etc. to store in the camera. It can use
the parameters to adjust the camera’s position. Operation is easy to call preset through joy s
tick and other equipment storage. The maximum preset number is 128,from 1 to 128.
Preset setting: Adjust the camera to the just position(include pan and tilt position‟s selection,
the camera zoom, focus and iris etc.), enter the preset number, pressing PRESET key and
keep at least for 5 seconds, then the preset set success.
Call preset:: Call preset is that the camera return to beforehand position quickly and
accurately. Enter preset number, pressing PRESET key and success.
Some preset numbers have special function, no longer have preset function. For exam
ple, The number 33 and 34 are fixed command, you can‟t program these two preset.
The number 33th is flip command which used for 180 º flip. The number 34th is used
for call 0º
command, the lens will run to camera‟s 0º position.
7.5 RANDOM SCANNING
Call number 97
th
then begin random scan; Direction and angles of scanning are all ra
ndom.
7.6 FRAME SCANNING
Call number 98
th
then activate frame scan, namely 360 degrees continuous loop scan;
The speed of frame scan can be set in OSD menu.
7.7 AUTO SCANNING
Call number 99
th
then start auto scan, namely sector scan.
The scan scope which contain scan left limitation, right limitation, and scan speed, cou