OPTIMUM
M A S C H I N E N - G E R M A N Y
Maintenance
Version 1.0.1 dated 2015-05-27
Page 72
Original operating instructions
TU3008 | TU3008V
GB
5.3
Lubricate and clean the lathe chuck
CAUTION!
Do not use compressed air to remove dust and foreign substances from the lathe chuck.
Coolant squirts on the lathe chuck and removes the grease from the master jaws. In order to
maintain the tensioning strength and accuracy of the lathe chuck for a long period of time, the
lathe chuck must be lubricated regularly. Insufficient lubrication will result in malfunctions at
reduced tensioning force, which affects the accuracy and causes excessive wear and seizing.
Depending on the chuck type and operating state, the tensioning force of a lathe chuck can
decrease by up to 50 percent of the nominal tensioning force.
A presumably securely clamped workpiece can then fall out of the chuck during processing.
Lubricate the lathe chuck at the worm and at the lubricating nipple. Lubricate the lathe chuck at
least once per week. The used lubricant should be of high quality and provided for high pres-
sure bearing surfaces. The lubricant should withstand the coolant and other chemicals.
Numerous different lathe chucks are available on the market which distinguish themselves con-
siderably based on the lubricating method. Follow the operating instructions of the correspond-
ing lathe chuck manufacturer.
5.4
Repair
5.4.1 Customer service technician
For any repair work request the assistance of an authorised customer service technician. Con-
tact your specialist dealer if you do not have customer service's information or contact Stürmer
Maschinen GmbH in Germany who can provide you with a specialist dealer's contact informa-
tion. Optionally, the
Stürmer Maschinen GmbH
Dr.-Robert-Pfleger-Str. 26
D- 96103 Hallstadt
can provide a customer service technician, however, the request for a customer service techni-
cian can only be made via your specialist dealer.
If repairs are performed by other qualified technical personnel, they must follow the instructions
in this operation manual.
ba
sed
o
n
op
er
ator
's
p
a
st ex
p
e
ri
e
n
ce
,
if ne
cess
ary
in
a
cco
rd
anc
e
wi
th Ge
rman
DGUV (BG
V
A3
)
elec
tron
ic
s
Electrical
inspection
"Electrical system“ on page 17
Interval
Where?
What?
How?