DIMENSION

SIP-3020/5, 4010/5, 404/5

248 (9.8)

02

(4.0)

266

(0.5)

90

(3.6)

2

(0.83)

75 (3.0)

6

(4.57)

7. (0.67)

3

(0.5)

96

(3.78)

2

(0.83)

OPTION

OPM-WT, AWT-3 

-Audio Walk Tester

AVF- 

 

-Area View Finder

SIP-MINIHOOD 

-Sun/Snow shield

SIP-HU 

 

-Heating unit

* UL-8: All option equipment are not evaluated by UL.

Cautions>>

When SIP-HU is used, the power for SIP unit should be  

22 - 26V AC.

These units are designed to detect movement to activate CCTV 

system.  Being only part of a complete surveillance system, 

we cannot accept responsibility for any damage or other 

consequences resulting form the activation of the unit.

This product confirms to the EMC Directive 2004/108/EC.

Specifications and design are subject to change without prior 

notice.

SPECIFICATIONS

2

Applicable 

models

SIP-3020/5

SIP-4010/5

SIP-404/5

Model

SIP-3020/5 SIP-400/5

SIP-404/5

Detection method

Passive infrared

Coverage

(Main area)

30 x 20m

(00 x 65ft.)

40 x 0m

(30 x 33ft.)

40 x 4m

(30 x 3ft.)

* Environmental condition may effect to the size of 

coverage area.

* It may be reduced to 90% in the worst case.

Coverage

(Creep zone)

3×5 m (0×6 ft.) at 2.3 m (7.6ft.) height

6×9 m (20×30 ft.) at 4 m (3ft.) height

Detection angle adjustable

Number 

of 

detection 

zones

Main area

74 zones

48 zones

24 zones

Creep 

zone

36 zones

Mounting height

2.3 to 4m (7.6 to 3ft.)

Power input

 - 6V DC

22 - 26V AC 

* UL-6

With optional 

heating unit

22 - 26V AC 

* UL-6

Current draw

45mA max. (2V DC)

85mA max. (24V AC)

 

* UL-6

With optional 

heating unit

425mA max. (24V AC) 

* UL-6

Operation 

indicator

Far alarm 

and 

Near alarm

Red LED

Creep zone 

alarm

Red LED

Alarm period

Approx. 2 sec.

Warm-up period

Approx. 60 sec.

Detection range 

selector

Far area: ON / OFF

Alarm interval period

0 / 5 / 30 / 60 sec.

Detection logic 

selector

AND/OR

Tamper output 

* UL-7

N.C. 28V DC, 0.1A max.

Trouble output 

* UL-7

N.C. 28V DC, 0.2A max.

Alarm 

output

 

* UL-7

Main area

N.C.28V DC, 0.2A max.

N.O.28V DC, 0.2A max.

Creep 

zone

N.C.28V DC, 0.2A max.

N.O.28V DC, 0.2A max.

Sensitivity selector

Far: SH/H/M/L Near: SH/H/M/L

Creep zone: SH/H/M/L

Operating 

temperature

Without 

optional 

heating 

unit

-25 to +60°C (-3 to +40°F)

With 

optional 

heating 

unit

-40 to +60°C (-40 to +40°F)

 

* UL-6

IP rating

Main unit :IP65

Chassis   :IP55

Dimensions  

(H × W × D)

248 x 102 x 266 mm

(9.8 x 4.0 x 10.5 in.)

Weight

1.4 kg (48 oz.)

Accessories

2 Screws

2 Nylon anchors

 Paper template

 Allen key

 Area masking seal

 Tweezers

 Instruction manual

 Area plate

 Fixing rubber form

* UL-6: Not evaluated by UL.

* UL-7: All relay outputs are resistive load only.

OPTEX CO., LTD. (JAPAN)

URL: http://www.optex.net/

OPTEX INC. (U.S.)

URL: http://www.optexamerica.com/

OPTEX DO BRASIL LTDA. (Brazil)

URL: http://www.optex.net/br/es/sec/

OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)

URL: http://www.optexeurope.com/

OPTEX SECURITY SAS (France)

URL: http://www.optex-security.com/

OPTEX SECURITY Sp.z o.o. (Poland)

URL: http://www.optex.com.pl/

OPTEX (DONGGUAN) CO.,LTD.

SHANGHAI OFFICE (China)

URL: http://www.optexchina.com/

OPTEX KOREA CO.,LTD. (Korea)

URL: http://www.optexkorea.com/

OPTEX PINNACLE INDIA, PVT., LTD. (India)

URL: http://www.optex.net./in/en/sec/

OPTEX TECHNOLOGIES B.V.

(The Netherlands)

URL: http://www.optex.nl/

Unit:mm (inch)

Содержание SIP-3020/5

Страница 1: ... area Built in creep zone detector Double dual pyro elements Anti vandalism functions Anti rotation function with accelerometer Anti masking function with photo beam Reinforced polycarbonate housing Max 4m 13ft installation height Independent sensitivity selector for creep near far areas Detection logic selector Detection range selector Independent N C and N O outputs Adjustable alarm interval tim...

Страница 2: ...l TAMPER OUTPUT It is detected when the cover is opened It is detected when the main unit is removed from its base Anti Rotation Damage sustained by the main unit is detected If the main unit is impacted in a horizontal or vertical direction and if the position of the main unit has changed damage sustained by the main unit will be detected UL 2 All relay outputs of Alarm Trouble are resistive load...

Страница 3: ... detection area Adjust the angle of the main unit in a vertical direction so that you can cover the desired detection area Cautions If the mounting wall is at an angle the arrow of the main unit may exceed the top or bottom limit of Angle adjustment guide Always check this using the area viewfinder or the walk tester If the detection area is too high or too low an object outside the detection area...

Страница 4: ... and check that the detection area is correct REDWAVE REDWAVE MICROWAVE REDWAVE ALARM OUTPUT CELL BATTERY POWER SUPPLY FROM SENSOR POWER OFF REDWAVE PIR NEAR REDWAVE PIR FAR MEGARED FAR MEGARED NEAR REDWALL REDWIDE WALKTESTER REDWALL REDWIDE MEGARED CONNECTION SELECT SWITCH MODE SELECT SWITCH POWER SELECT SWITCH OPM WT 1 When the power selector switch is turned to POWER SUPPLY FROM SENSOR position...

Страница 5: ...te mounted in the main unit Step 7 Near area Use the masking plate mounted in the main unit 8 1 Attach the masking seal an accessory to the area mirror surface 8 2 Creep zone cannot be masked Connect the walk tester optional to the sensor unit and check that the detection area is correct 1When the power selector switch is turned to POWER SUPPLY FROM SENSOR position after plugging the cable into th...

Страница 6: ...t an interval 4 different times to suspend the alarm signal output For example if you set this interval to 30 seconds no more alarm signals will be output for 30 seconds after the output of the first alarm signal If no pedestrians are detected for more than 30 seconds the system returns to the standby mode Then when a pedestrian is detected the alarm signal will be output SELECTOR POSITION FUNCTIO...

Страница 7: ...0 0 0 0 20 30 50 40 TOP VIEW Installation height 2 3 m 7 6ft SIDE VIEW Installation height 2 3 m 7 6ft TOP VIEW Installation height 4 0 m 13ft TOP VIEW Installation height 2 3 m 7 6ft DETECTION AREA 6 Applicable models SIP 3020 5 SIP 4010 5 SIP 404 5 TOP VIEW Installation height 4 0 m 13ft SIDE VIEW Installation height 4 0 m 13ft Applicable models SIP 3020 5 SIP 4010 5 SIP 404 5 Applicable models ...

Страница 8: ...the window does not fall Do not pull the window using excessive force After you have masked the detection areas mount the window and place the excessive nylon wire loop inside the main unit How to remove the window Applicable models SIP 3020 5 SIP 4010 5 SIP 404 5 3 4 1 2 5 6 7 0 m 5 5 0 5 0 5 ft 30 20 0 0 0 20 30 40 50 50 40 7 6 5 4 2 3 7 TOP VIEW Installation height 4 0 m 13ft Applicable models ...

Страница 9: ...cable models SIP 3020 5 SIP 4010 5 SIP 404 5 1 2 3 4 m 5 0 5 ft 0 0 0 m 5 0 5 ft 0 0 0 4 3 2 3 2 SIP 40 0 5 SIP 404 5 Far area mirror Rib Rib Rib Near area mirror 2Attach the masking plate to the mirror and secure it to the ribs 3 Insert the fixing rubber form to secure the knob of the masking plate 1 Remove the masking plate from the storage and check the detection area and the mirror you use by ...

Страница 10: ...indow and the cover rain drops may be able to enter into the main unit Mount the cover 1 2 TERMINATION PROCEDURE 9 8 2 Masking the Detection Areas using Masking Seals Using the tweezers an accessory carefully attach the area masking seals an accessory to the near area mirror F 6 E 6 F E D C B E E E E E E D D D D D D C C C C C C B B B B B B F F F F F F 6 4 2 5 3 1 6 4 2 5 3 1 6 4 2 5 3 1 6 4 2 5 3 ...

Страница 11: ...reet Where People Walk or Cars Drive by the Detection Area Points Reduce the size of the detection area so that it does not include any public streets Check to see that the arrow of the main unit is within the width of Angle adjustment guide on the adjustment screw Using the area viewfinder check to see that the detection area does not include any public streets If the detection area does go beyon...

Страница 12: ...ional heating unit 425mA max 24V AC UL 6 Operation indicator Far alarm and Near alarm Red LED Creep zone alarm Red LED Alarm period Approx 2 sec Warm up period Approx 60 sec Detection range selector Far area ON OFF Alarm interval period 0 15 30 60 sec Detection logic selector AND OR Tamper output UL 7 N C 28V DC 0 1A max Trouble output UL 7 N C 28V DC 0 2A max Alarm output UL 7 Main area N C 28V D...