Sens.Select.SW.
Sens.Select.SW.
Far area
Far area Near area
Near area Creep zone
Creep zone
5-2
Detection Logic Selector Switch
Dip switch
1
Applicable
models
SIP-3020/5
SIP-4010/5
SIP-404/5
Detection area of SIP-3020/5, SIP-400/5
and SIP-404/5 consist of two types of plane
detection areas in an alternative manner
constructed by two pairs of pyro-elements, for
the near and the creep zone.
SELECTOR
POSITION STATUS
FUNCTION
UP
OR
Factory
default
A sensor signal is output when an
object is detected in either of the two
detection areas.
* Use this mode when you adjust
the detection area. Switch to AND
mode after you have finished the
detection area adjustment.
DWN
AND
Use this mode to reduce instances
of incorrect detection of objects. The
sensor signal is output only when
an object is detected within the two
detection areas. If any objects are
blocking multiple detection areas,
use OR mode.
5-3
Detection Range Selector Switch
Dip switch
2
SELECTOR
POSITION STATUS
FUNCTION
UP
OFF
Cancels the far area detection. The
detection area is reduced as shown
below.
DWN
ON
Factory
default
Enables the far area detection.
Applicable
models
SIP-3020/5
SIP-4010/5
SIP-404/5
Applicable
models
SIP-3020/5
SIP-4010/5
SIP-404/5
Cautions>>
If you cancel the far area detection, the detection
distance is limited to approximately 20 meters (65ft.). Be
sure to readjust and check the detection area using the
area viewfinder and the walk tester.
5-4
Alarm Interval Switch
Dip switch
3-4
Applicable
models
SIP-3020/5
SIP-4010/5
SIP-404/5
You can set an interval (4 different times) to
suspend the alarm signal output.
For example, if you set this interval to 30
seconds, no more alarm signals will be output
for 30 seconds after the output of the first alarm
signal. If no pedestrians are detected for more
than 30 seconds, the system returns to the
standby mode.
Then, when a pedestrian is detected, the alarm
signal will be output.
SELECTOR
POSITION
FUNCTION
0 sec
(Factory
default)
5 sec 30 sec 60 sec
* UL-5: If movement occurs continuously during the time interval directly after the first
alarm, the time period for no alarms starts over.
( )
( )
FUNCTION SETTING
Applicable
models
SIP-3020/5
SIP-4010/5
SIP-404/5
Sens.Select.SW.
Sens.Select.SW.
Far area
Far area Near area
Near area Creep zone
Creep zone
573050
573050
UP DWN
Alarm
Alarm Creep
Creep
Sens.Select.SW.
Sens.Select.SW.
Far area
Far area Near area
Near area Creep zone
Creep zone
573050
573050
UP DWN
Alarm
Alarm Creep
Creep
Cautions>>
If the red LED keeps blinking for approx. 60 seconds
after turning the power on, turn the power off and then on
again.
5-
Sensitivity Selector Switch for Far
Area, Near Area and Creep Zone
Applicable
models
SIP-3020/5
SIP-4010/5
SIP-404/5
You can change the sensitivity for far area
detection, near area detection and creep zone
detection independently.
SELECTOR
POSITION
FUNCTION
SH
Suitable for sites requiring a
level of sensitivity higher than
“H”
H
Suitable for sites requiring a
level of sensitivity higher than
“M”
M
(Factory
default)
Suitable for standard
applications
L
Suitable for hostile and narrow
area
Far area detection is canceled.
Far area detection is canceled.
Near area sensitivity
selector switch
Far area sensitivity selector
switch
Walk tester
connector
Tamper
switch
Operation indicator
(See Step .)
: Detection logic selector
(AND or OR)
2: Detection range selector switch
3,4: Alarm holding time selectors
Creep zone
sensitivity selector
switch