Warranty conditions:
1.
H4eko boilers can be installed only by a company with a valid authorization to
perform its installation and maintenance.
2.
Installation project must be elaborated in accordance with applicable
regulations.
3.
The heating system must be filled with water, which meets the requirements of
ČSN 07 7401 and especially its hardness must not exceed the required
parameters. Using antifreeze fluids is not recommended by the manufacturer.
4.
Connecting the boiler to the system must be done in accordance with applicable
regulations and standards.
5.
The flue gas path must be checked by chimney-sweeper before commissioning
of the boiler. Require an audit report covering the basic parameters of the flue
gas path, including the diameter of the chimney, its length and chimney draft.
6.
Flue should not be longer than one meter (distance between the boiler and
chimney inlet) and should be fitted with a cleaning opening. The flue can be
extended only if the chimney draft was measured and recorded no longer than
30 cm from the boiler outlet and it meets the minimum operating draft, see
chapter Main parameters.
7.
H4eko boiler must be installed in a separate boiler room, specially adapted for
heating. The boiler room must have sufficient space for installation and
maintenance of the boiler. There must be sufficient circulation of fresh air for
combustion. The boiler must never be installed in open spaces or balconies, in
areas inhabited by people. Such as kitchen, living room, bathroom, bedroom,
also in areas where there are explosive and flammable materials.
8.
It is recommended to install the boiler on a concrete base from fire-proof
material. There should be guaranteed minimum handling area around boiler
and pellet hopper. 60cm rear and lateral sides, 100cm from the front of the
boiler and hopper.
9.
When installing and operating the boiler it is necessary to keep a safe distance
of 200 mm from flammable materials.
10.
It is disallowed to store fuel behind the boiler or next to the boiler within a
distance smaller than 800 mm.
11.
It is interdicted to store the fuel between two boilers in the boiler room.
12.
We recommend to keep the distance between the boiler and fuel min. 1000 mm
or store the fuel in a different room.
13.
Guarantee fuel tyepes are brown coal and wood logs.