background image

 

HOBO RX3000 Remote Monitoring Station Manual 

 

22 

Fault 
Code # 

Description 

Action to Take 

Removing Smart Sensors

). Also check 

that the smart sensor cables are ok. 

132 

Analog 
Excitation 
Bus Fault 

Check the analog sensor connection 
and the excitation settings for the 
sensor in HOBOlink. 

Battery Information 

The station uses one rechargeable 4 volt, 10Ah, sealed lead-
acid battery. Use the AC adapter (AC-U30), solar panel (SOLAR-
xW), or external DC power cable (CABLE-RX-PWR) with your 
own charging device to keep the battery charged. If using a 
solar panel, the quality and quantity of solar light can affect 
whether the battery is sufficiently charged to last through the 
night and cloudy periods. Without a charging device connected, 
expected battery life varies based on the ambient temperature 
where the station is deployed, the logging or sampling interval, 
frequency of connections to HOBOlink, the number of channels 
that are active, excitation in analog modules, the number of 
tripped alarms, and other factors. Deployments in extremely 
cold or hot temperatures, a logging interval faster than 1 
minute, or a sampling interval faster than 15 seconds can 
impact battery life. Estimates are not guaranteed due to 
uncertainties in initial battery conditions and operating 
environment. 

Use the following table as a guideline for estimating how long 
the station will run using a fully charged battery and no source 
of external power. For these examples, the station has up to 10 
smart sensors installed and no excitation enabled for the 
analog sensor module. 

Connection Interval 

Logging Interval 

Typical Run Time 

10 minutes 

1 minute 

20 days 

1 hour 

15 minutes 

50 days 

6+ hour 

30 minutes 

75 days 

 
All communications will stop if the battery voltage drops below 
3.9 V. The station will stop logging if the battery voltage drops 
below 3.6 V. If the station has stopped logging due to low 
battery voltage, plug in an AC adapter, solar panel, or external 
power source to recharge it. It may take several minutes for the 
station to power back up; the lower the remaining voltage, the 
longer it will take for power to return. Also note that it will take 
longer for power to return with a solar panel than with an AC 
adapter. If the charging device is not recharging a dead battery, 

Important:

 Due to the self-discharge characteristics of this type 

of battery, it is imperative that you charge the battery for at 
least 12 hours every six months at minimum, even if you are 
not actively using the station. Otherwise, permanent loss of 
battery capacity may occur. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.

.com

[email protected]

1.800.561.8187

Содержание HOBO RX3000 Series

Страница 1: ...ns AC power adapter AC U30 solar panel SOLAR xW or external power source 5 V DC to 17 V DC with external DC power cable CABLE RX PWR Rechargeable Battery Service Life Typical 3 5 years when operated i...

Страница 2: ...dBm for 1 0 Mbps Cellular RX3003 and RX3004 Wireless Radio RX3003 GSM GPRS EDGE Quad band 850 900 1800 1900 MHz UMTS HSPA Five band 800 850 900 1900 2100 MHz RX3004 GSM GPRS EDGE Quad band 850 900 180...

Страница 3: ...s product as complying with all relevant directives in the European Union EU RXMOD RXW 922 See last page Table of Contents Device Components and Operation 4 LCD Operation 5 Setting up the Station 7 a...

Страница 4: ...ation Charging Port Use this port to plug in an AC adapter solar panel or external power source to keep the battery charged see Setting up the Station and Battery Information USB Port Use this port to...

Страница 5: ...dicates the last connection to HOBOlink was ok indicates there was a problem with the last connection check the Connections log in HOBOlink Smart Sensor and Module Status This part of the LCD shows th...

Страница 6: ...losed c In this example the first and third relays are open and the second one is closed This will blink in the lower right part of the LCD when a firmware update is underway It will display which mod...

Страница 7: ...er module on the left and the relay module on the right for easier cable routing c Using a Phillips head screwdriver tighten the screw at the bottom of each module In this example an analog module is...

Страница 8: ...eckbox f Enter the IP Address Subnet Mask Gateway and DNS Server Consult your Network Administrator for the appropriate addresses to complete these fields g Click Save in the RX3000 Manager Click Done...

Страница 9: ...or one smart sensor through the larger of the two cable openings and plug it into one of the 10 smart sensor connectors Repeat for any additional smart sensors b Press the Select button to view the sm...

Страница 10: ...ion 4 GND EX RTN 4 GND EX RTN 5 CH2 SIGNAL 5 CH4 SIGNAL 6 CH2 GND 6 CH4 GND 7 SHIELD 7 SHIELD Note All four input channels share the same common ground Analog Module Functional Diagram To connect rela...

Страница 11: ...section on your station s page in HOBOlink c Click Save or click Next Smart Sensors Logging and Configuration You can configure both the global settings that affect all smart sensors logging interval...

Страница 12: ...he sensor measurement type for that mote g Click one of the mote measurement types from menu under Module Wireless Sensors Logging as shown in the following example h Type a label for the measurement...

Страница 13: ...he four analog sensor channels from the menu such as Channel 1 shown in this example g Select Enable Graph if you want the sensor data to be graphed in HOBOlink h Select Enable this channel if you wan...

Страница 14: ...ired 4 Under Select Data to Export choose the name of the custom data export you want to be delivered or follow the previous set of steps to set up a custom data export 5 Under Data Destination select...

Страница 15: ...ps send an email or text or close open or pulse one of the three relays if a relay module is installed For email or text enter the details and then select Send on Clear Also if you want an email or te...

Страница 16: ...is inserted through the bottom of the station case Do not reconnect the power on the station until the mote is plugged in as shown 7 Plug in the battery and charging device and wait for the device to...

Страница 17: ...ocess make sure the mote is in a vertical upright position and within range of the station 7 Repeat steps 4 6 for any additional motes to add 8 Press the Search button the magnifying glass on the RX30...

Страница 18: ...t in the connection schedule Also note that the station will connect to HOBOlink when the device is powered up and when you press the Start button For RX3003 and RX3004 cellular models All connections...

Страница 19: ...location Check the signal strength on the mote LCD on the location where you want to place the mote If there is only one or two bars on the signal strength indicator consider moving the mote to a loca...

Страница 20: ...d for outdoor and weatherproof deployments and recommended for harsh indoor environments where debris could enter the station 1 Make sure all sensors and cables are installed including the solar panel...

Страница 21: ...n or mote before opening it Check that all cables and wires are free of damage such as cracks cuts and splits Make sure cables and wires are still fastened securely and any conduit is still intact Ver...

Страница 22: ...ranteed due to uncertainties in initial battery conditions and operating environment Use the following table as a guideline for estimating how long the station will run using a fully charged battery a...

Страница 23: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV t...

Страница 24: ...minutes in air moving 1 m sec with protective cap Operating Temperature Range 40 C to 75 C 40 F to 167 F Environmental Rating Weatherproof 0 to 100 RH intermittent condensing environments For best re...

Страница 25: ...mounted properly the housing is weatherproof but not waterproof Refer to the station manual and Tripod Setup Guide for more information regarding setting up stations Connecting the Sensor to a Statio...

Страница 26: ...erval See Measurement Operation for more information Operating Temperature Range 40 to 75 C 40 to 167 F Environmental Rating Sensor and Cable Jacket Weatherproof Housing Three cup polycarbonate anemom...

Страница 27: ...place 5 Adjust the height of the sensor in the cross arm as necessary using one of the following methods and then tighten the nut and bolt until the cross arm just starts to deform a Loosen the tri cl...

Страница 28: ...ogging at a 1 second interval the sensor will report the same wind speed its calculated average for three samples before calculating and reporting a new value for another three samples Gust speed is t...

Страница 29: ...rproof Service Life 4 to 6 years typical depending upon environmental conditions Housing Injection molded plastic housing and vane static dissipating base lead free silicon bronze nose and aluminum mo...

Страница 30: ...until snug 2 Insert the sensor mounting rod into the cross arm allowing the mounting rod to protrude 1 3 cm 1 2 inch from the bottom of the cross arm 3 Tighten the nut and bolt until the rod is sligh...

Страница 31: ...urself so that the station is that number of degrees to the west of magnetic north 4 While viewing the sensor through binoculars instruct another person to rotate the sensor mounting rod to point the...

Страница 32: ...logging at a 1 second interval the sensor will report the same wind direction its calculated average for three samples before calculating and reporting a new value for another three samples Measuremen...

Страница 33: ...clamp unlimited with screws Compatible Sensors S THB 00x S TMB M0xx TMCx HB TMCx HD and external sensors from U23 00x or MX230x Maximum Sensor Diameter 1 22 cm 0 48 inches Mount temperature or temp R...

Отзывы: