F-4600 With LCD Flow Meter Manual 06/18 - 2020-3 / 35874
Page
32
30184
Year to Date Volume Total - Liters
Input Register
Floating Point Register (2 of 2)
30185
Year to Date Volume Total - ft
3
Input Register
Floating Point Register (1 of 2)
30186
Year to Date Volume Total - ft
3
Input Register
Floating Point Register (2 of 2)
30187
Year to Date Volume Total - m
3
Input Register
Floating Point Register (1 of 2)
30188
Year to Date Volume Total - m
3
Input Register
Floating Point Register (2 of 2)
30205
Previous Year Volume Total - Gal
Input Register
Floating Point Register (1 of 2)
30206
Previous Year Volume Total - Gal
Input Register
Floating Point Register (2 of 2)
30207
Previous Year Volume Total - Liters
Input Register
Floating Point Register (1 of 2)
30208
Previous Year Volume Total - Liters
Input Register
Floating Point Register (2 of 2)
30209
Previous Year Volume Total - ft
3
Input Register
Floating Point Register (1 of 2)
30210
Previous Year Volume Total - ft
3
Input Register
Floating Point Register (2 of 2)
30211
Previous Year Volume Total - m
3
Input Register
Floating Point Register (1 of 2)
30212
Previous Year Volume Total - m
3
Input Register
Floating Point Register (2 of 2)
30229
User Defined Volume Total - Gal
Input Register
Floating Point Register (1 of 2)
30230
User Defined Volume Total - Gal
Input Register
Floating Point Register (2 of 2)
30231
User Defined Volume Total - Liters
Input Register
Floating Point Register (1 of 2)
30233
User Defined Volume Total - ft
3
Input Register
Floating Point Register (1 of 2)
30234
User Defined Volume Total - ft3
Input Register
Floating Point Register (2 of 2)
30235
User Defined Volume Total - m3
Input Register
Floating Point Register (1 of 2)
30236
User Defined Volume Total - m3
Input Register
Floating Point Register (2 of 2)
30253
Auxiliary Pulse Input Count- Input 1
Input Register
Floating Point Register (1 of 2)
Unitless count. Value
is representative of the
total number of pulses
received on input.
30254
Auxiliary Pulse Input Count- Input 1
Input Register
Floating Point Register (2 of 2)
Unitless count. Value
is representative of the
total number of pulses
received on input.
30255
Auxiliary Pulse Input Count- Input 2
Input Register
Floating Point Register (1 of 2)
Unitless count. Value
is representative of the
total number of pulses
received on input.
30256
Auxiliary Pulse Input Count- Input 2
Input Register
Floating Point Register (2 of 2)
Unitless count. Value
is representative of the
total number of pulses
received on input.
30257
Auxiliary Pulse Input Count- Input 3
Input Register
Floating Point Register (1 of 2)
Unitless count. Value
is representative of the
total number of pulses
received on input.
30258
Auxiliary Pulse Input Count- Input 3
Input Register
Floating Point Register (2 of 2)
Unitless count. Value
is representative of the
total number of pulses
received on input.
30259
Run Hours
Input Register
Floating Point Register (1 of 2)
30260
Run Hours
Input Register
Floating Point Register (2 of 2)
30261
Meter Status
Input Register
Short Integer Register
0 Normal
7 Low Signal Quality
8 Comm error
9 Low Supply Voltage
10 System Fault