background image

- 8 -

WEEK DURING USE.

 

Diagram 4 

MULTIPLE FLOOR PLAN

 

Diagram 5

 

Installation:

 

Activation

 

Press  test  button  and  hold  it  for  more  than  3  seconds 

until LED lights, and release it within 2 seconds, the unit 

will generate a “beep” indicating that it is activated and 

ready to detect status.

 

CAUTION:

 this unit must activated prior to installation. 

Failure to perform step will result in a non functioning 

smoke alarm!

 

• Turn  the  alarm  body  counterclockwise  and  take  off  the

bracket.

• Hold the bracket in the installation position as specified in

the Recommended Locations, mark installation holes of the

bracket with pencil.

• Drill  the  two  marked  installation  holes  with  a  3/16  inch

(5mm)  drill  bit.  Tap  the  two  plastic  grommets  into  holes

with hammer.

• Remove  locking  plug  from  the  bracket  with  screwdriver  if

necessary  (Refer  to  Diagram  6).  This  is  an  optional

additional locking in place feature.

• Mount the bracket to the ceiling by inserting and tightening

the  supplied  screws  into  plastic  grommets.  (Refer  to

Diagram 7).

• Fit  the  alarm  on  the  bracket  and  turn  the  alarm  body

clockwise, until fully inserted on the bracket.

• Optionally insert locking plug into the gap between bracket

and  bottom  cover  for  locking  alarm  in  place  (Refer  to

800.607.054

1  

|

  31100 Solon Rd STE 16 Solon, OH 44139

Содержание 54866

Страница 1: ...hould install an alarm on every level of the home particularly outside sleeping rooms Each alarm should be placed in the middle of the ceiling of each room to be protected Typical single storey dwelling installation recommendations Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet l...

Страница 2: ...ing explosive or intentional and others are caused by carelessness or safety hazards In such circumstances Smoke may not reach the alarm QUICKLY ENOUGH to ensure safe escape Therefore the installation of smoke alarms is not a substitute for practicing fire safety in the home 8 Smoke alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fir...

Страница 3: ...ce the trouble indication for 10 hours but it will reset automatically after 10 hours During this condition the unit will continue to operate normally and detect smoke and sound an alarm This action only temporarily silences the chirp NOTE As the battery in this unit is not replaceable a low battery signal is an indication of end of life Therefore the alarm MUST be replaced as soon as possible Fau...

Страница 4: ...essing the test button temporarily silence this warning tone for 10 hours it will again prompt you to replace the alarm after 10 hours Maintenance and Cleaning In addition to weekly testing the alarm requires periodic cleaning to remove dust dirt and debris Clean the alarm at least once a year to remove dust dirt or debris Use a vacuum cleaner with a soft brush vacuum all sides and covers of smoke...

Страница 5: ...can return to your retailer 4 if the unit is out of warranty please replace another new alarm An intermittent chirp accompanied by a red LED flash The battery is depleted please replace the smoke alarm every 40 seconds Smoke alarm chirp occurs every 40 seconds only alarm goes into fault mode Clean smoke alarm Please refer to the maintenance and cleaning section Replace smoke alarm if the problem p...

Страница 6: ...east one alarm on every floor level Locate an alarm in every bedroom Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread ...

Страница 7: ... the ceiling In such units install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling see Diagram 2 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall For minimum protection install at least one alar...

Страница 8: ...the Recommended Locations mark installation holes of the bracket with pencil Drill the two marked installation holes with a 3 16 inch 5mm drill bit Tap the two plastic grommets into holes with hammer Remove locking plug from the bracket with screwdriver if necessary Refer to Diagram 6 This is an optional additional locking in place feature Mount the bracket to the ceiling by inserting and tighteni...

Страница 9: ...ed if no sound it indicates a defective alarm refer to the Trouble shooting section for a solution or return to your retailer during warranty WARNING To prevent injury this unit must be securely attached to the wall or ceiling in accordance with the installation instructions Diagram 7 Diagram 6 800 607 0541 31100 Solon Rd STE 16 Solon OH 44139 ...

Страница 10: ...austed Must also allow the battery to fully discharge for at least one day 2 Use this method to scrap the alarm if the is the end of life during out of warranty 3 Please return to retailer and change another alarm during the Warranty 4 Cannot install the smoke alarm again once he battery is discharged Diagram 9 SERVICE AND WARRANTY Company warrants to the original consumer Purchase each new smoke ...

Отзывы: