background image

- 3 -

Operation:

Testing

 

Test the unit weekly to ensure proper operation by pressing 

the test button. this will sound the alarm if the electronic 

 

circuitry, horn, and battery are working properly. If no alarm 

sounds, the battery may be depleted or another problem, refer 

to “Trouble shooting” section for a solution.

 

DO  NOT 

use  an  open  flame  to  test  your  alarm,  you  could 

damage the alarm or ignite combustible materials and start a 

structure fire.

CAUTION:

 Due to the loudness (85 decibels) of the alarm,

 

Always  stand  an  arms-length  away  from  the  unit  when 

testing.  Test  the  alarm  weekly  to  ensure  proper  operation. 

Erratic or low sound coming from your alarm may indicate a 

defective  alarm.  Refer  to  “Trouble  shooting”  section  for  a 

solution.

 

NOTE: WEEKLY TESTING IS REQUIRED.

 

LED indicators

 

This smoke alarm is equipped with red LED indicators.

 

Standby  Condition

:  The  red  LED  will  flash  every  40 

seconds  to  indicate  that  the  smoke  alarm  is  operating 

properly.

 

Alarm  Condition

:  When  the  alarm  senses  products  of 

combustion  and  goes  into  alarm,  the  red  LED  will  flash 

rapidly  (one  flash  per  second).The  rapid  flashing  LED  and 

pulsating  alarm  will  continue  until  the  air  is  cleared  or  the 

test button is released.

 

Silence Condition:

 The red LED will flash every 8 seconds 

as long as the alarm is in Hush mode.

 

Low  battery  trouble  indication: 

An  intermittent  “chirp” 

accompanied by a red LED flash every 40 seconds indicates 

a  low  battery,  you  may  press  the  test  button  to  silence  the 

trouble indication for 10 hours, but it will reset automatically 

after 10 hours. During this condition the unit will continue to 

operate normally and detect smoke and sound an alarm. This 

action only temporarily silences the chirp.

 

NOTE:

  As  the  battery  in  this  unit  is  not  replaceable,  a  low 

battery  signal  is  an  indication  of  end  of  life.  Therefore  the 

alarm MUST be replaced as soon as possible!

 

Fault  indication:

  This  chirp  will  occur  between  the  flashes 

of the red LED indicator light.

 

Battery  discharge  Condition:

  The  red  LED  will  always 

light ( This is another red LED of other position).

 

NOTE

:

  When  the  unit  chirps  once  every  40  seconds, 

pressing  the  test  button  temporarily   silences  this  warning 

tone  for  10  hours

Refer  to  “Trouble  shooting”  section  for 

solutions, if the fault signal reactivates, 

you MUST replace 

 

the  unit  with  a  new  alarm  at  once 

or  contact  you  retailer 

during warranty. 

 

SMOKE  SENSING  CHAMBER  OPERATION:  This  alarm 

will  “chirp”  if  any  of  the  components  in  the  smoke  sensing 

chamber fail. This chirp will occur between the flashes of the 

red LED indicator light. (If the chirp occurs at the same time 

as the red LED flash, indicating a low battery information).

 

Alarm silence 

When the alarm sounds check for a fire first, After verifying 

that it is not a fire the alarm can be silenced by pushing the 

test button This will silence the alarm for approx 10 minutes. 

The red LED will flash once every 8 seconds indicating the 

smoke  alarm  is  in  the  silence  mode.  Smoke  alarms  are 

designed  to  minimize  nuisance  alarms,  but  combustion 

particles from cooking may set off the alarm if the alarm is 

800.607.054

1  

|

  31100 Solon Rd STE 16 Solon, OH 44139

Содержание 54866

Страница 1: ...hould install an alarm on every level of the home particularly outside sleeping rooms Each alarm should be placed in the middle of the ceiling of each room to be protected Typical single storey dwelling installation recommendations Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet l...

Страница 2: ...ing explosive or intentional and others are caused by carelessness or safety hazards In such circumstances Smoke may not reach the alarm QUICKLY ENOUGH to ensure safe escape Therefore the installation of smoke alarms is not a substitute for practicing fire safety in the home 8 Smoke alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fir...

Страница 3: ...ce the trouble indication for 10 hours but it will reset automatically after 10 hours During this condition the unit will continue to operate normally and detect smoke and sound an alarm This action only temporarily silences the chirp NOTE As the battery in this unit is not replaceable a low battery signal is an indication of end of life Therefore the alarm MUST be replaced as soon as possible Fau...

Страница 4: ...essing the test button temporarily silence this warning tone for 10 hours it will again prompt you to replace the alarm after 10 hours Maintenance and Cleaning In addition to weekly testing the alarm requires periodic cleaning to remove dust dirt and debris Clean the alarm at least once a year to remove dust dirt or debris Use a vacuum cleaner with a soft brush vacuum all sides and covers of smoke...

Страница 5: ...can return to your retailer 4 if the unit is out of warranty please replace another new alarm An intermittent chirp accompanied by a red LED flash The battery is depleted please replace the smoke alarm every 40 seconds Smoke alarm chirp occurs every 40 seconds only alarm goes into fault mode Clean smoke alarm Please refer to the maintenance and cleaning section Replace smoke alarm if the problem p...

Страница 6: ...east one alarm on every floor level Locate an alarm in every bedroom Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread ...

Страница 7: ... the ceiling In such units install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling see Diagram 2 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall For minimum protection install at least one alar...

Страница 8: ...the Recommended Locations mark installation holes of the bracket with pencil Drill the two marked installation holes with a 3 16 inch 5mm drill bit Tap the two plastic grommets into holes with hammer Remove locking plug from the bracket with screwdriver if necessary Refer to Diagram 6 This is an optional additional locking in place feature Mount the bracket to the ceiling by inserting and tighteni...

Страница 9: ...ed if no sound it indicates a defective alarm refer to the Trouble shooting section for a solution or return to your retailer during warranty WARNING To prevent injury this unit must be securely attached to the wall or ceiling in accordance with the installation instructions Diagram 7 Diagram 6 800 607 0541 31100 Solon Rd STE 16 Solon OH 44139 ...

Страница 10: ...austed Must also allow the battery to fully discharge for at least one day 2 Use this method to scrap the alarm if the is the end of life during out of warranty 3 Please return to retailer and change another alarm during the Warranty 4 Cannot install the smoke alarm again once he battery is discharged Diagram 9 SERVICE AND WARRANTY Company warrants to the original consumer Purchase each new smoke ...