- 4 -

located  close  to  the  cooking  area.  To  minimize  the 

occurrence of   false alarms, smoke alarms must be installed 

a  minimum  of  10  feet  (3meters)  from  the  nearest  cooking 

appliance.   If  you  accidentally  let  some  smoke  into  the 

alarm  cause  alarm,  you  can  open  the  doors  and  windows. 

Turn on the fan blew it. The alarm will silence (test button) is 

extremely  useful  in  a  kitchen  area  or  other  areas  prone  to 

nuisance alarms. The silence feature is to be used only when 

a  known  alarm  condition,  such  as  smoke  from  cooking 

activates the alarm. The smoke alarm is desensitised by push 

the alarm silence (silence mode) on the smoke alarm cover, 

the  alarm  will  silence  to  indicate  that  the  alarm  is  in  a 

temporarily  desensitised  condition.  The  smoke  alarm  will 

automatically  reset  after  approximately  10  minutes,  if  after 

this  period,  particles  of  combustion  are  still  present,  the 

alarm  will  sound  again.  The  alarm  silencer  (silence  mode) 

can  be  repeatedly  until  the  air  has  been  cleared  of  the 

condition causing the alarm.

 

NOTE: 

Dense  smoke  will  override  the  alarm  silencer  and 

sound a continuous alarm.

 

CAUTION:

  Before  using  the  alarm  silence  (silence), 

identify  the  source  of  the  smoke  and  be  certain  a  safe 

condition exists.

 

DANGER: 

If the alarm sounds, and it is not being tested, it 

means  the  unit  is  sensing  smoke, 

THE  SOUND  OF  THE 

ALARM  REQUIRES  YOUR  IMMEDIATE  ATTENTION  AND 

ACTION.  

 

Low Battery status:

 

An intermittent "chirp" accompanied by a flashing red LED 

indicates  once  every  40  seconds  indicating  that  the  battery 

has  reached  a  low  voltage.  And  this  is  a  non-replaceable 

battery  alarm,  so  you  need  to  replace  a  new  smoke  alarm 

within 7 days, In order to avoid noise to disturb your sleeping 

in the night time, pressing the test button temporarily silence 

 

this warning tone for 10 hours

it will again prompt you to 

replace the alarm after 10 hours. 

 

Maintenance and Cleaning:

In  addition  to  weekly  testing,  the  alarm  requires  periodic 

cleaning to remove dust, dirt, and debris. Clean the alarm at 

least  once  a  year  to  remove  dust,  dirt,  or  debris.  Use  a 

vacuum  cleaner  with  a  soft  brush,  vacuum  all  sides  and 

covers of smoke alarm. This alarm has a low battery monitor 

which  will  cause  the  alarm  to  “chirp”  approx  every  40 

seconds  and  the  red  LED  flash  once  at  the  same  time  for  a 

minimum  of  7  days  when  the  battery  gets  low.  If  there  is  a 

defective battery or other failures, you can refer to “Trouble 

shooting”  for  solution,  if  there  are  still  failures  during 

warranty, you can return to your retailer.

 

WARNING: The battery is sealed and is not replaceable. 

Please replace with new alarm if the low battery chirp occurs.

 

IMPORTANT:

 Do not attempt to remove the cover to clean 

inside. This will void the warranty.

 

WHAT TO DO WHEN THE ALARM SOUNDS

 

1.

 

Alert  small  children  in  the  home  to  quickly  follow  the

family escape plan.

2.

 

Leave  immediately  by  your  escape  plan.  Every  second

counts,  so  don’t  waste  time  getting  dressed  or  picking  up

valuables.

3.

 

In leaving, don’t open any inside door without first feeling

its  surface.  If  hot,  or  if  you  see  smoke  seeping  through

cracks,  don’t  open  that  door!  Instead,  use  your  alternate

exit.  If  the  inside  of  the  door  is  cool,  place  your  shoulder

against  it,  open  it  slightly  and  be  ready  to  slam  it  shut  if

heat and smoke rush in.

4.

 

Stay  close  to  the  floor  if  the  air  is  smoky.  Breathe

shallowly through a cloth, wet if possible.

5.

 

Once outside, go to your selected meeting place and make

sure everyone is there.

6.

 

Call  the  fire  department  from  your  neighbor’s  home  -not

from yours!

7.

 

Don’t return to your home until the fire officials say that it

800.607.054

1  

|

  31100 Solon Rd STE 16 Solon, OH 44139

Содержание 54866

Страница 1: ...hould install an alarm on every level of the home particularly outside sleeping rooms Each alarm should be placed in the middle of the ceiling of each room to be protected Typical single storey dwelling installation recommendations Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet l...

Страница 2: ...ing explosive or intentional and others are caused by carelessness or safety hazards In such circumstances Smoke may not reach the alarm QUICKLY ENOUGH to ensure safe escape Therefore the installation of smoke alarms is not a substitute for practicing fire safety in the home 8 Smoke alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fir...

Страница 3: ...ce the trouble indication for 10 hours but it will reset automatically after 10 hours During this condition the unit will continue to operate normally and detect smoke and sound an alarm This action only temporarily silences the chirp NOTE As the battery in this unit is not replaceable a low battery signal is an indication of end of life Therefore the alarm MUST be replaced as soon as possible Fau...

Страница 4: ...essing the test button temporarily silence this warning tone for 10 hours it will again prompt you to replace the alarm after 10 hours Maintenance and Cleaning In addition to weekly testing the alarm requires periodic cleaning to remove dust dirt and debris Clean the alarm at least once a year to remove dust dirt or debris Use a vacuum cleaner with a soft brush vacuum all sides and covers of smoke...

Страница 5: ...can return to your retailer 4 if the unit is out of warranty please replace another new alarm An intermittent chirp accompanied by a red LED flash The battery is depleted please replace the smoke alarm every 40 seconds Smoke alarm chirp occurs every 40 seconds only alarm goes into fault mode Clean smoke alarm Please refer to the maintenance and cleaning section Replace smoke alarm if the problem p...

Страница 6: ...east one alarm on every floor level Locate an alarm in every bedroom Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread ...

Страница 7: ... the ceiling In such units install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling see Diagram 2 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall For minimum protection install at least one alar...

Страница 8: ...the Recommended Locations mark installation holes of the bracket with pencil Drill the two marked installation holes with a 3 16 inch 5mm drill bit Tap the two plastic grommets into holes with hammer Remove locking plug from the bracket with screwdriver if necessary Refer to Diagram 6 This is an optional additional locking in place feature Mount the bracket to the ceiling by inserting and tighteni...

Страница 9: ...ed if no sound it indicates a defective alarm refer to the Trouble shooting section for a solution or return to your retailer during warranty WARNING To prevent injury this unit must be securely attached to the wall or ceiling in accordance with the installation instructions Diagram 7 Diagram 6 800 607 0541 31100 Solon Rd STE 16 Solon OH 44139 ...

Страница 10: ...austed Must also allow the battery to fully discharge for at least one day 2 Use this method to scrap the alarm if the is the end of life during out of warranty 3 Please return to retailer and change another alarm during the Warranty 4 Cannot install the smoke alarm again once he battery is discharged Diagram 9 SERVICE AND WARRANTY Company warrants to the original consumer Purchase each new smoke ...

Отзывы: