5 - 7.5 HP Direct Drive Owner’s Manual

3

II.  General Assembly

1

5

5

5

2

3

9b

9e

9b

9c

(12) 5/16” x 1” Bolts

(12) 5/16” Washers

(12) 5/16” Nuts

(4) 3/8” x 1” Bolts

(4) 3/8” Washers

(4) 3/8” Nuts

Caution

Check Dust Bin Frequently For

Smoldering Materials. Empty Bin Before

Leaving Shop.

Drum cover must be in place when system

is operating to prevent motor overheating!

An airtight seal between the cyclone and

drum will provide the necessary resistance

needed to prevent motor overheating!

Caution

Caution:

If exhaust air is vented outside you must provide

make up/return air.
Flue gases (carbon monoxide) can be drawn into

the shop from furnaces, water heaters or other

appliances.

To avoid personal injury or property damage, read owner’s manual thoroughly before

installing and operating system. (Read section on collector location and fire hazards.)

This collector is for use with WOOD DUST ONLY!

Keep fire extinguishers handy at all times.

Do not use this product to collect other types of dusts or fumes.

(Fire or explosion may occur!)

Do not introduce sparks or sources of ignition into collector.

Personnel should stay at least 20 ft. away from operating system. (Deflagration Hazard)

Empty and check dust bin frequently for possible smoldering materials.

Rotating blades inside. Keep hands and objects away.

Do not operate system unless COMPLETELY assembled with dustbin.

(Personal injury or motor damage may occur!)

Consult local fire marshal before installing.

Follow all Federal, State, Local and NFPA codes when installing system.

To reduce the risk of injury from moving parts - unplug before servicing.

To reduce the risk of electric shock - unplug before cleaning or servicing.

Read Before Installing and Operating!

For All

Systems

Caution

(8) 5/16” Washers

(8) 5/16” Nuts

Filter Maintenance

Failure to follow filter maintenance instructions

in owner’s manual will cause filter to be

damaged.
Blow down filter at end of day with compressed

air per owner’s manual or blow down when back

pressure reaches 3” water gauge - whichever

comes first. Never allow gauge to reach 5”.

- XXK050100 - 1 phase - XXK070300- 3 phase

9a

0

1

2 3 4

5

INCHES W.C.

8a 8b

8c

8e

8d

7.5 hp Direct Drive System - XXK070300 3 phase
1. Motor/Blower Assembly  BXI050100-1ph -BXI070300 - 3ph
     1a.Motor -1 ph / BMZ070370-7.5 hp 3 phase 3 ph
     1b.Fan Housing5 & 7.5 hp 16” - BHX070000
     1c.Fan Wheel - BWX160000
     1d.7.5 hp Shaft Spacer - BBS070001
     1e.Bolt 5/16” - 24x1” Left Thread - AFB155160
     1f. Motor Plate - RMP000000
     1g. 5/16” Washer - AFW155160
     1h. Bolt 1/2”-13x3/4” HH (4) - AFB155200
     1j. Fender Washer 5/16” x 1 1/2” (2) - AFW170000
     1k. Washer Flat 3/8” (8) -  AFW190000
     1l. Whiz Lock Nut 3/8” GR5 (4) - AFT000004
     1m. Bolts 3/8” - 16x1” HHGR% (4) - AFS015100
2. Cyclone Barrel - SXI070000
3. Cyclone Cone 5-7.5 HP 27” - SCX070000
4. Bolts 3/8” 16x1” (16) - AFS015100
   Washers 3/8” (32) - AFW190000
   3/8” Wiz Lock Nuts (16) - AFT000004
   5/16” Wiz Lock Nuts (16) - AFT155175
5. Neoprene Gasket (30’) - RGZ000000
6. Owners Manual - ZBM000006
7. Plenum Filter Assembly - FXK020100
    7a. Plenum Assembly 2 Filters 5-7.5 hp DD - FPX020700
    7b. Dust Bin 16” Dia. x 12” high (2) - FPZ016000
    7c. Filter Cartrigde 130 sq. ft. 18”dia. x 62” L (2) - FCS186200
    7d. Internal Silencer - BSC180000
8. Filter Efficiency Gauge Kit - FXK000000
     8a.Filter Efficiency Gauge 0”-5” H20 - VRG001005

     8b. Vinyl Tubing Clear 5/16” O.D. - VRV003125 (8’)

     8c. Static Pressure Tip - VRP001875

     8d. Mounting Flange for Pitot Tube - VRP010000
     8e. Filter Efficiency Gauge Bracket - FXX000000
9. 55 Gal. Steel Drum Kit - SEK551001  

Standard

     

 9a. Drum Lid w/ 10” Ring - SEX551000

     

 9b. Hose Clamps (2) - ACB120000

    

 9c. 55 Gal. Steel Drum - SES550000

 9e. Flex Hose (10” dia. x 1’) - DHF100000

10. Stand Standard with Plenum Support - STZ070000
       Hardware  for stand

10a. (38) 3/8” 16 x 1” Bolts - AFS015100

      

10b. (38) 3/8”  Flat Washers - AFW190000

      

10c. (38) 3/8” Wiz Lock Nuts - AFT000004

11. Decal - (1) Oneida Logo - ZBC000015

12. Labels

     12a. Rotation Label - ZBC000029

     12b. Caution / Exhaust Label - ZBS000004

     12c. General Caution Label - ZBS000001

     12d. Filter Maintenance Label - ZBS000007

     12e. Caution / Check Frequently Label - ZBS000006

     12f. Caution / Drum Cover Label - ZBS000005

7

7d

7a

7b

5 & 7.5 HP

Direct Drive Cyclonic

Dust Collectors

Oneida Air Systems, Inc.   1001 West Fayette St., Syracuse, N.Y.  13204

Phone 1-800-732-4065   315-476-5151   Fax 315-476-5044   www.oneida-air.com

Owner’s Manual

6

Содержание XXK050100

Страница 1: ...5 7 5 HP Direct Drive Cyclonic Dust Collectors Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual 10_08...

Страница 2: ...l before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 System Start Up Information Direct Drive Configurations Gene...

Страница 3: ...troyed motors due to improper wiring or incorrect installation Caution The Dust Collector Fan Blower is heavy Handling and installation should always be performed by experienced and trained personnel...

Страница 4: ...water gauge whichever comes first Never allow gauge to reach 5 XXK050100 1 phase XXK070300 3 phase 9a 0 1 2 3 4 5 INCHES W C 8a 8b 8c 8e 8d 7 5 hp Direct Drive System XXK070300 3 phase 1 Motor Blower...

Страница 5: ...tion Class F4 Voltage 208 230 460 Amperage 19 6 18 4 9 2 Made in U S A Integral Fan Blower 7 5hp 2 Pleated Cartridges 260 sq ft Spun Bonded polyester BIA ZH1 487 test Rated C Captures 99 99 of test ma...

Страница 6: ...IV Dimensions O A S 2008 c 5 7 5 HP Direct Drive Owner s Manual 5 10 031 I D 7 64 I D 1 25 Flange 52 25 82 or 106 for Twin Drum 60 134 25 or 158 25 33 Approx 100 33 56 105 or 129 122 or 146...

Страница 7: ...nt B Back Requires Fork Truck for installation 1 Bolt stand together laying down Orient square cross brace 7 Cross brace 6 must be oriented to face plenum Note There will be NO lower brace on front so...

Страница 8: ...sher on bolt then attach hex nut Tip the fan housing and cone upright The system is very top heavy Cyclone Inlet and Fan Blower are independent Filters can be to the right or left of the unit 7 Bolt F...

Страница 9: ...nnector is air tight or motor damage could result Stay clear of fan exhaust while collector is operating Collector Hose Clamp Hose Clamp Flex Hose Dust Bin 6 7 Attach the ductwork from the woodworking...

Страница 10: ...shown on the nameplate for all other motors Do not use protection with larger capacities than recommended Three phase motors must have all three phases protected 2 Cleanliness Keep both the interior...

Страница 11: ...nclip and carefully empty dust bin All steps should be done with a dust mask and eye protection and System off 1 Compressed air from outside Blast air along pleats of the filter at about a 20 angle Bl...

Страница 12: ...ound Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw Top View Outlet Inlet 1 Blue 8 Red J Brown 5 Black Power Line 1 Tie together and insu...

Страница 13: ...g across the Line Starters Nema Type 1 Enclosure with Start Stop in cover and class 10 overload Industrial switches can also be purchased through your local electrician Due to varying electrical codes...

Страница 14: ...pe too small a hood port or too small a branch line See branch line diameter chart in ductwork guide Be sure that your filters are clean See filter cleaning directions Filters filling with large chips...

Страница 15: ...low 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an ex...

Страница 16: ...idental contingent special or consequential damages arising from the use of our product Oneida Air Systems does not warrant or authorize use of wood dust collectors for other purposes This includes wo...

Страница 17: ...e to the port labeled on the back of the pressure gauge 5 Make sure the tubing is not crushed or kinked along its entire length cut shorter if necessary 4 When the gauge rises to 3 it s time to clean...

Страница 18: ...3600 RPM motors are to be relubricated every 5500 hours Table 1 Service Conditions Table 2 Lubrication Interval Multiplier Per Baldor specifications add 30 ounces 8 4 grams of Mobil Polyrex grease by...

Страница 19: ...per must be installed by a licensed electrician The jumper is not required if you are using 3 phase power Remove the blank plate and install the start stop pushbutton into the starter cover You must m...

Страница 20: ...ntrol circuit Most OAS Starters are shipped with 240v coils Plug the Start Stop Push Button Assembly into keyed receptacle As shown below Run power to the starter and from the starter to your motor Se...

Страница 21: ...t Install this Jumper for Single O Using the Same Gauge Wire Sized Connected to L1 L2 Omit this Wire for Single O Move this Wire to L2 for Single O Note Select Size of Fuse or Circuit Breaker Per Arti...

Отзывы: